{"product_id":"sonda-pro-mereni-teploty-a-vlhkosti-vzduchu","title":"Probe for measuring air temperature and humidity","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRelay\n  for temperature and humidity control. Humidity and temperature controller with separate\n  outputs and hysteresis, dimensions 72x36x100 mm, flush mounting. HT-310 TENSE.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMain\n  characteristics:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eType\n  sensor used for humidity and temperature controller - one common - NT-310;\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRange\n  measured temperature: -19.9 °C..+80.0 °C; measurement step 1 °C;\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRange\n  measured humidity: 5 %....95 %; measurement step 1 %;\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePrinciple\n  control - ON-OFF;\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2\n  output contact groups: switching control contact \"°C OUT\", 2A\n  resistive load for temperature and normally open \"%RH OUT\" 2A\n  resistive load for humidity\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2\n  operating modes of temperature control \"Cooling\" and \"Heating\"\n  (\"COOLING\" and \"HEATING\")\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2\n  operating modes of humidity control \"Dehumidification\"\n  \"Humidification\";\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSeparate\n  setting hysteresis parameters for temperature and humidity control; Choice between\n  absolute, relative temperature value or sensor error for ALARM contact\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOption\n  setting the delay for turning ON OUT for COOLING mode (used for\n  compressors); Option to set a fixed offset for temperature or humidity (when\n  change in the length of the sensor wire);\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eProtection\n  with the password of the parameters set in the temperature controller;\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eEnergy\n  independent memory (EEPROM) for data storage;\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eEasy\n  disconnection \/ connection to the controlled device - connection is made using\n  quick connectors.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eExtended\n  operating voltage range - 100...240V, 50-60 Hz\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThis\n  the controller can also be used as a hygrostat, humidity meter, moisture meter or\n  hygrometer (hygrometer, hygrometer), thermostat, thermal relay or in other words\n  relay for measuring humidity and air temperature!\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAttention!!!\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWhen\n  when connecting the temperature sensor, observe polarity - failure to comply with this\n  rules may lead to incorrect operation of the temperature controller and damage to the sensor.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWhen\n  when connecting the controller to power, use a 250mA 250V fuse, use\n  cable with the appropriate cross-section, follow electrical safety rules.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFor\n  signal contacts use shielded twisted pair with grounded shielding.\n  Place this cable in locations... Protect from strong electromagnetic\n  fields, contactors, or power cables.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style='font-size:12.0pt;line-height:115%;font-family:\"Aptos\",sans-serif;\nmso-ascii-theme-font:minor-latin;mso-fareast-font-family:Aptos;mso-fareast-theme-font:\nminor-latin;mso-hansi-theme-font:minor-latin;mso-bidi-font-family:\"Times New Roman\";\nmso-bidi-theme-font:minor-bidi;mso-ansi-language:CS;mso-fareast-language:EN-US;\nmso-bidi-language:AR-SA'\u003eWarning, important! Although this thermostat is designed for\nmeasuring temperatures below -20 degrees and above 55 degrees, the device itself\ninstalled where the temperature ranges from -20...+55 degrees. Otherwise,\nthe plastic casing may deform and the thermostat itself may fail.\u003c\/span\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102889386317,"sku":"NT-310","price":37.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_1757ec93-57f1-487f-886d-557bf3f8eba9.png?v=1718448943","url":"https:\/\/pelek.eu\/en-ie\/products\/sonda-pro-mereni-teploty-a-vlhkosti-vzduchu","provider":"pelek","version":"1.0","type":"link"}