{"product_id":"rele-hladiny-kapaliny-pro-naparovaci-kotle-studnu-nebo-nadrz","title":"Liquid level relay for steam boilers (well or tank)","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRelay\n  for water level control in the boiler is installed in two condenser\n  water heating systems (steam generators) with control for switching off electric heating\n  in the absence of water in the tank.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDiagram\n  the relay connection for water level control in the heater\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePerform\n  connection according to the diagram\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCom\n  Elect. - basic electrode (not part of the set).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTank\n  Elect - electrode for monitoring the liquid level in the well (not part of\n  set).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBoiler\n  Elect - electrode for monitoring the liquid level in the boiler - tank (not\n  part of the set).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRes\n  Elect - electrode for monitoring the liquid level to turn on the liquid heater\n  (not part of the set)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRes.\n  Out - output for connecting the liquid heater\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWater\n  Not - output for connecting the signal indicator (turning on\/off the heater)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnect\n  (Com Elect) to the body of the well TANK and to the boiler (tank, container) - BOILER.\n  If the tank is not a conductor, connect (Com Elect) to the electrode for monitoring\n  liquid levels.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLevel\n  water level in the tank (TANK) drops - until the water level is lower than the sensor level\n  liquid level (Tank Elect), the pump will turn on and a green light will illuminate\n  indicator \"motor operation\". If the water level falls below this\n  sensor (Tank Elect), the motor will stop functioning and the indicator \"operation\n  the motor\" will turn off.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLevel\n  of water in the boiler, tank, vessel (Boiler) increases - when the tank is filled to\n  level electrode (Boiler Elect), the pump will turn off (the green indicator\n  \"pump operation\" indicator will stop lighting) and will cease to pump water.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLevel\n  the water level in the boiler (tank, vessel) drops - when the water level falls below the\n  of the liquid level sensors (Boiler Elect), a 10-second delay will be initiated\n  the pump motor will start after the set time has elapsed\n  (the 'motor operation' indicator will light up) by pumping water to the level\n  sensors (Boiler Elect).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIn the boiler\n  a level electrode is also installed to control the electric heating\n  liquid level (Res Elect). When the water rises to the sensor level (Res Elect),\n  the indicator will turn off and the water heater will turn on. If the water level drops below the\n  sensor (Res Elect) from turning on, the heater will shut down and the indicator will light up. The use of\n  electrodes for measuring the water level in the heater will prevent the electric\n  of heating in the tank - boiler when there is no water present, and the indicator will assist you\n  to determine whether the heater is functioning. The indicator may serve as a level indicator\n  water (below-above the electrode Res Elect). This option will prevent the heater from failing\n  (operation without liquid - idle) and will save you money.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eElectrodes\n  (liquid level sensors) are not included in the delivery.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDo not forget\n  please order water level sensors and a 2-amp circuit breaker for protection\n  input and output channels of this device (3 pieces).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated\n  voltage: 220 V, alternating current.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRange\n  operating voltage: from 90% to 110%.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  frequency: 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLosses:\n  \u0026lt;3 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAmbient\n  temperature: -40...+50\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnection\n  sensor and power supply: screw\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eInstallation: DIN rail or mounting panel\u003c\/span\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102873657677,"sku":"SSR-19","price":17.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_5330a31b-c4f8-4f0f-a372-e5554ffed005.png?v=1718448684","url":"https:\/\/pelek.eu\/en-ie\/products\/rele-hladiny-kapaliny-pro-naparovaci-kotle-studnu-nebo-nadrz","provider":"pelek","version":"1.0","type":"link"}