{"product_id":"elektronicke-pocitadlo-pulzu-pocitadlo-impulzov","title":"Electronic pulse counter \/ Pulse counter","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDetailed\n  description\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCounter\n  impulses for panel DS-48\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(2x\n  4-digit display: 1x counter, 1x target value)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eGeneral\n  specifications of the pulse counter DS-48:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x\n  4-digit display, 1x preset value,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1x\n  output relay OUT,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ecounter\n  hours\/down\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCounts\n  signals from mechanical switches, inductive PNP\/NPN proximity sensors and\n  of inputs from the incremental encoder.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eProtection\n  with a password.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOptional\n  input frequency: 20, 50, 2500, 7500 Hz\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCalibration\n  constant: 0,001.....9,999\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOptional\n  decimal point: 0, 0,0, 0,00, 0,000\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOptions\n  combination of functions: 7 input functions \/ 9 output functions:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  counting,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  counting down,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  counting\/counting from two inputs simultaneously,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- pause\n  in counting\/counting controlled by the second input,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  input negation controlled by the second input,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  counting\/subtracting from the rising edge \/ falling edge \/ both edges simultaneously,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  counting on the rising edge \/ subtracting on the falling edge \/ negation function with the second\n  input\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAdjustable\n  \"OFFSET\" of the calculated value\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOUTPUT\n  relay: will turn on when the value is reached and will hold until RESET or a pulse in\n  range of 0.1.....999.9 seconds\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRemembers\n  the value of the pulse count and the state of the output relay OUT at the last failure\n  power and can be restored after the first power on.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRESET\n  by the button on the front panel or by a signal at the RESET terminal (12).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMemory\n  EEPROM for storing settings.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eNotes\n  for installation:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUse\n  shielded and twisted signal cable and ground the shielding. Keep all\n  signal cables away from circuit breakers, inductive loads, devices\/cables that\n  emit electrical noise, and power cables.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePrevent\n  environmental influences, such as humidity, vibration, pollution, and high\/low\n  temperature.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOn\n  the device's network\/power input, use a fuse (F250mA 250VAC).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFor\n  for power use a suitable cable. During installation, adhere to safety\n  regulations.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBefore\n  preferably use the option (Input = Phs1), select (Frequency = 20)\n  for counting pulses of the mechanical ON-OFF switch,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eselect\n  the optimal minimum input frequency that suits your application.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePre\n  Input = 1u2u, 1u2d, Phs2; the frequency of the input signal must be a maximum of ½\n  selected input frequency, if both inputs are used.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePre\n  Inpt = Phs4; the frequency of the input signal must not exceed 1\/4 of the selected\n  input frequency, if both inputs are used.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  parameters:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDimensions\n  \/ \u003c\/span\u003e\u003cspan lang=\"CS\"\u003e​​cutout: 48x48x96 mm \/ 44x44 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay:\n  2x4-digit 7-segment LED display.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eNumber\n  inputs: 2 x (Max: 7500 Hz, 5-30 V)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eType\n  input: mechanical switch, inductive PNP\/NPN sensor, encoder output\n  NPN\/PNP\/totem-pole\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInput\n  frequency: 20, 50, 2500, 7500 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSelection\n  NPN sensor: Before the NPN, connect terminal \"npn select\" (8) to terminal \"+12V\" (9) and\n  then select the NPN sensor connected to input Cp1(10) and Cp2 (11).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReset\n  the input is always PNP.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBefore\n  totem or PNP sensors will not connect with 'npn select'.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReset\n  signal: terminal (12), minimum 10 ms, + signal (only PNP) (5.....30 V)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower supply\n  voltage: 100...240 V AC, 50-60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConsumption\n  power: \u003c 8 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOutput\n  (OUT):\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1x relay\n  SPDT 250VAC, 2A, resistive load, terminals 4=COM, 3=NO, 5=NC,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1x\n  SSR control - NPN, 30V, max. 100mA, terminal 13=SSout, 14=GND\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower supply\n  sensor: terminal (9) 12 VDC, 50 mA (max.), unregulated\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConversion\n  temperature: -20°C ... +55°C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eAltitude of the supervisor: \u003c2000m\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102860681549,"sku":"DS-48","price":54.33,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_725ef8bb-f534-4b7c-8a82-c88145b0b63c.png?v=1718448511","url":"https:\/\/pelek.eu\/en-ie\/products\/elektronicke-pocitadlo-pulzu-pocitadlo-impulzov","provider":"pelek","version":"1.0","type":"link"}