{"title":"All products","description":"\u003cp\u003e\u003c\/p\u003e","products":[{"product_id":"potenciometr-10-kω-5-kω-jednootackovy-ip64-prumer-zadlabacky-22-mm","title":"Potentiometer 10 kΩ \/ 5 kΩ single turn IP64 recess diameter 22 mm","description":"\u003cp\u003e\u003cstrong\u003ePotentiometer 10 kΩ \/ 5 kΩ single turn IP64 groove diameter 22 mm TENSE (made in Turkey) PTS-10\/PTS-5\/WL9PT5K\/WL9PT10K\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe 10k \/ 5k single turn potentiometer is designed for use with frequency converters for manual motor speed control or any other manual control task. The potentiometer can be installed in standard push button stations (plastic or aluminum) or directly on the control panel \/ control board in a hole with a diameter of 22 mm. The wires are connected by a screw connection, the maximum cross-section of the wire is 2.5 mm\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"10 kΩ","offer_id":49102855209293,"sku":"WL9PT10K","price":181.0,"currency_code":"CZK","in_stock":false},{"title":"5 kΩ","offer_id":49102855242061,"sku":"WL9PT5K","price":180.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file.jpg?v=1759325839"},{"product_id":"tk30s-merici-transformator-proudu-100-5-150-5-200-5-250-5-300-5-400-5-500-5","title":"TK30S - Measuring current transformer 100\/5 150\/5 200\/5 250\/5 300\/5 400\/5 500\/5","description":"\u003cp\u003e\u003cstrong\u003ePlug-in measuring transformer for primary rated currents from 100 to 500 A, secondary current 5 A, rated power 2.5 VA, available in 0.5 accuracy class.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003ePlug-in current converter for indirect measurement of sinusoidal alternating currents\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eFixing of the transformer is done either by means of fixing feet, which are part of the delivery.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"100\/5","offer_id":49102855438669,"sku":"TK30S1005102","price":331.0,"currency_code":"CZK","in_stock":false},{"title":"150\/5","offer_id":49102855471437,"sku":"TK30S1505203","price":250.0,"currency_code":"CZK","in_stock":true},{"title":"200\/5","offer_id":49102855504205,"sku":"TK30S2005203","price":331.0,"currency_code":"CZK","in_stock":true},{"title":"250\/5","offer_id":49102855536973,"sku":"TK30S2505203","price":331.0,"currency_code":"CZK","in_stock":true},{"title":"300\/5","offer_id":49102855569741,"sku":"TK30S3005203","price":163.0,"currency_code":"CZK","in_stock":false},{"title":"400\/5","offer_id":49102855602509,"sku":"TK30S4005203","price":331.0,"currency_code":"CZK","in_stock":false},{"title":"500\/5","offer_id":49102855635277,"sku":"TK30S5005203","price":331.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_099ba47b-b021-4274-bd47-57f22f323828.png?v=1718448376"},{"product_id":"tk30-merici-transformator-proudu-150-5-200-5-250-5-300-5-400-5-500-5-600-5","title":"TK30 - Measuring current transformer 150\/5 200\/5 250\/5 300\/5 400\/5 500\/5 600\/5","description":"\u003cp\u003e\u003cstrong\u003ePlug-in measuring transformer for primary rated currents from 150 to 600 A, secondary current 5 A, rated powers 1 to 10 VA, available in 0.5S accuracy classes.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003ePlug-in current converter for indirect measurement of sinusoidal alternating currents\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eFixing of the transformer is done either by means of fixing feet, which are part of the delivery.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"150\/5","offer_id":49102855831885,"sku":"TK301505301","price":420.0,"currency_code":"CZK","in_stock":true},{"title":"200\/5","offer_id":49102855864653,"sku":"TK302005302","price":420.0,"currency_code":"CZK","in_stock":true},{"title":"250\/5","offer_id":49102855930189,"sku":"TK302505303","price":420.0,"currency_code":"CZK","in_stock":true},{"title":"300\/5","offer_id":49102855962957,"sku":"TK303005303","price":420.0,"currency_code":"CZK","in_stock":true},{"title":"400\/5","offer_id":49102855995725,"sku":"TK304005305","price":420.0,"currency_code":"CZK","in_stock":true},{"title":"500\/5","offer_id":49102856028493,"sku":"TK305005306","price":207.0,"currency_code":"CZK","in_stock":false},{"title":"600\/5","offer_id":49102856061261,"sku":"TK306005307","price":420.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_0d8a0152-be81-4776-8229-1033b8a89cd9.png?v=1718448380"},{"product_id":"tk40-merici-transformator-proudu-300-5-400-5-500-5-600-5-800-5","title":"TK40 - Measuring current transformer 300\/5 400\/5 500\/5 600\/5 800\/5","description":"\u003cp\u003e\u003cstrong\u003ePlug-in measuring transformer for primary rated currents from 300 to 800 A, secondary current 5 A, rated powers 1.5 to 10 VA, available in 0.5S accuracy classes.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003ePlug-in current converter for indirect measurement of sinusoidal alternating currents\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eFixing of the transformer is done either by means of fixing feet, which are part of the delivery.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"300\/5","offer_id":49102856126797,"sku":"TK403005302","price":487.0,"currency_code":"CZK","in_stock":true},{"title":"400\/5","offer_id":49102856159565,"sku":"TK404005303","price":487.0,"currency_code":"CZK","in_stock":true},{"title":"500\/5","offer_id":49102856192333,"sku":"TK405005306","price":517.0,"currency_code":"CZK","in_stock":true},{"title":"600\/5","offer_id":49102856225101,"sku":"TK406005306","price":295.0,"currency_code":"CZK","in_stock":true},{"title":"800\/5","offer_id":49102856257869,"sku":"TK408005307","price":623.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_bc86a823-a5d3-47b5-8f39-68db7e78ca16.png?v=1718448384"},{"product_id":"tk80-merici-transformator-proudu-1500-5","title":"TK80 - Measuring current transformer 1500\/5","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCurrent\n  transformer 81x13, 1500\/5A -0.5S - 20VA — 80mm, Tension\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTension\n  current transformers enable precise measurement and control of electrical\n  parameters in alternating current systems. They convert high current values to lower,\n  safe for measuring devices, allowing for effective control and management of\n  electrical systems.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  specifications\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCoefficient:\n  1500\/5A\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLoad capacity:\n  20VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eClass\n  accuracy 0.5S\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTerminal block\n  Non-removable cover; for conductors with a large cross-section; Made of brass for\n  greater safety\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eHousing   Non-flammable,\n  self-extinguishing ABS\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInstallation\n  KK0001 or KK0002\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePrimary\n  winding 80 x 10 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRound\n  conductor Ø 65 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eT-resistance\n  against short-circuit current Ith = 60 * In\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eT-resistance\n  against exposure to constant current Id = 1 * In\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAmbient\n  temperature (operating hours) -25°C~+85°C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated\n  frequency 50 Hz ... 60 Hz\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLimit\n  value of the inrush current FS 5\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTesting\n  voltage 3 kV for 1 minute\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMax.\n  system voltage 0.72 kV\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eStandards:\n  IEC 60044-1, IEC 61869-2, VDE 0414-1, DIN57414, BS3938, BS7626, EN 61869\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAdvantages\n  current transformers:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eHigh\n  accuracy: provide reliable measurements for precise control of electrical\n  parameters.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWide\n  range of rated currents: allows selecting the optimal model for specific\n  needs.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eVarious\n  sizes: different window sizes provide flexibility in installation and\n  compatibility with various conductors.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReliability\n  and durability: made from high-quality materials that guarantee long\n  longevity.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new=\"\" roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eThe choice of current transformers ensures\nstable operation of electrical systems and measurement accuracy, which is a key factor\nfor effective energy consumption management.\u003c\/span\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102856290637,"sku":"TK8015005310","price":992.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_b512c720-38b3-4cd7-aca7-09190ae42021.png?v=1729770118"},{"product_id":"da-din-ampermetr-digitalni-pro-ac-stridave-proudy-100-nebo-250-amperu","title":"DA-DIN Ammeter digital for AC alternating currents of 100 or 250 amperes","description":"\u003cp\u003e\u003cstrong\u003eAmmeter digital for AC 100 or 250 amperes True RMS, indirect measured, measuring transformer included, TENSE panel meters\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe ammeter is mounted on a standard 35mm DIN rail\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"100A","offer_id":49102856323405,"sku":"DA-120","price":1003.0,"currency_code":"CZK","in_stock":true},{"title":"250A","offer_id":49102856356173,"sku":"DA-300","price":1003.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/7a4fb624ad2c4535f83b26d477459534.png?v=1764666382"},{"product_id":"dv-din-voltmetr-digitalni-pro-ac-stridave-napeti-0-500v-panelova-meridla","title":"DV-DIN Digital voltmeter for alternating voltage 0-500 V, panel meters","description":"\u003cp\u003e\u003cstrong\u003e0-500V True RMS AC Voltage Digital Voltmeter, TENSE Panel Meters\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe voltmeter is mounted on a standard 35mm DIN rail\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102856421709,"sku":"DV-DIN","price":930.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/d8562a5891d8b7425937013e01d56ebb.png?v=1759322699"},{"product_id":"frekvencni-citac-din-meric-kmitoctu-frekvence-digitalni-1-400hz-panelova-meridla","title":"Frequency Counter DIN Frequency Meter Frequency Digital 1-400Hz Panel Meters","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eEspecially\n  precise frequency meter of True RMS class for installation \u003c\/span\u003e\u003cspan lang=\"EN-GB\"\u003e\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-GB\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDIN\n  list. DF-DIN TENSE\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDF-DIN\n  is designed for monitoring the frequency range (from 1 Hz to 400 Hz) between phase and\n  phases or phase and neutral conductor.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDevice\n  is used to control frequency stability in single-phase and three-phase\n  systems, which is particularly important for industrial equipment, generators,\n  transformers and power systems.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThanks to\n  the three-digit LED display provides the frequency meter with a clear and quick display\n  data. The compact housing, simple installation, and high accuracy make Tense\n  DF-DIN optimal solution for panel mounting.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAreas\n  use\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eElectrical\n  switchgear\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIndustrial\n  switchgear\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBackup\n  power systems\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eGenerator\n  units\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRegulation\n  frequency in laboratories and testing devices\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  specification\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  voltage: 140-280 V AC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  frequency: 50\/60 Hz\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  power: \u003c3VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  temperature: -20 °C ..... + 55 °C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay:\n  1 x 3\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMeasuring\n  range: 1 Hz - 400 Hz\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnection:\n  terminal connection\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDiameter\n  cable: 2.5 mm2\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWeight:\n  135 g\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  height: \u003c2000 m\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eInstallation: on DIN rail\u003c\/span\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102856552781,"sku":"DF-DIN","price":1003.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/b8b654fce0119dc76483ee94d807d204.png?v=1759322675"},{"product_id":"digitalni-ukazatel-proudu-trifazovy-panelovy-ampermetr-trifazovy-vestavny","title":"Digital current indicator three-phase panel ammeter three-phase built-in","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDetailed\n  description\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDJ-A96T\n  three-phase digital ammeter on panel\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAmmeter\n  for monitoring current in a three-phase system with current measurement on individual\n  phases L1, L2, L3 using external current transformers.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower\n  voltage: 230V AC, device voltage \u0026lt;4VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRange\n  of current: 100mA...5.5A\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRange\n  of the current transformer: 5\/5A - 5000\/5A\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAccuracy\n  measurement +-2%\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePackaging\n  does not include current transformers, you can select them here.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWell\n  readable display 3x4 digits, height 14 mm.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDimensions\n  97.2x97.2mm for a cutout of 91x91mm, depth 45mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePrinciple\n  activities and settings:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnect\n  device according to the wiring diagram.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnect\n  current transformers with a ratio of xxxx\/5A according to the current load of your\n  system. Connect the wires of the current transformers to the input terminals\n  devices \"kx\" and \"lx\". The output from the current transformers to the ammeter may\n  to be a maximum of 5 A.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBefore\n  by starting the load measurement, after turning on the power, hold the \"Menu\" button for\n  2 seconds.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSet\n  the transformation ratio of the used transformers using the \"Up\"-\"Down\" buttons.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFor\n  to save the settings, hold the \"Menu\" button for 2 seconds.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnect\n  The load and ammeter will start displaying the current.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eZ\n  For safety reasons, it is always necessary to ground the measuring transformer.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  properties:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eType\n  relay: Semiconductor\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInput\n  voltage: 3...32 V DC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSwitched:\n  24...480 V AC. Not intended for motors\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDrop\n  voltage: \u0026lt; 3 V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eStarting\n  current: 5 mA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eVoltage\n  coils: 3...32 V DC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMax.\n  current: 25 A\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eElectrical\n  insulation strength: 2500 V AC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eControl method: switching when the current exceeds zero.\u003c\/span\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102857109837,"sku":"DJ-A96T","price":1099.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/5668b11ced30e9727cdcb5355cff5330.png?v=1759322558"},{"product_id":"dj-v96t-voltmetr-panelovy-digitalni-trifazovy-vestavny-pro-ac","title":"DJ-V96T Voltmeter panel digital three-phase built-in for AC","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThree-phase\n  digital panel voltmeter (electronic voltmeter for 3 phases) threaded\n  type for alternating current TENSE, DJ-V96T\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDevice\n  for simultaneous measurement of phase\/neutral voltage on three phases with output\n  current voltage values on three displays. The display mode is selected using\n  buttons on the front panel of the voltmeter.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUsage\n  device and principle of operation\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDevice\n  is intended for monitoring the voltage between phase and neutral conductor and also between phases.\n  It also displays the phase sequence.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAfter\n  after connecting the power supply, the values of voltages at inputs L1, L2 and L3 will be displayed.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIf\n  the screen displays the values of voltages of phases L1, L2 and L3, after pressing\n  the SELECT button will display the values of phase voltages L12, L23 and\n  L31. After pressing the SELECT button again, the display will show the phase\n  sequence.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIf\n  the phase sequence is correct, the display will show L1, L2, L3 from top to bottom.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIf\n  the phase sequence is incorrect, the display will show L1, L3, L2 from top to bottom.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  specification\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  voltage (Un): 140V - 300V AC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  frequency: 50\/60 Hz\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConsumption\n  power: \u003c4VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  temperature: -20°C.....+55°C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAccuracy\n  measurement: ±1%\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMeasuring\n  range (L-N): 5V - 300V AC (voltage in L1 must be at least 140V)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMeasuring\n  range (L-L): 5V - 500V AC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDimensions\n  mounting hole: 91x91 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eType\n  connection: Plug connector\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay:\n  3x3 digits, 14 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWeight:\n  Maximum 300 g\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  altitude: \u003c2000 meters\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDiameter\n  cable: 1.5 mm²\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eInstallation: Installation on the front panel\u003c\/span\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102857175373,"sku":"DJ-V96T","price":1225.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/1f424cf88494a6e470d8673076c8159d.png?v=1759322542"},{"product_id":"dav-72d-panelovy-digitalni-ampermetr-a-voltmetr-pro-ac-100-amperu-150v","title":"DAV-72D Panel Digital Ammeter and Voltmeter for AC 100 Amps, 150V","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePanel\n  digital multimeter 72x72 mm (electronic ammeter-voltmeter) single-phase,\n  manufactured by TENSE, includes a current transformer.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDAV-72D\n  is a digital combined voltmeter-ammeter, designed for continuous\n  monitoring:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ealternating\n  voltage (AC) between phase and neutral conductor,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eand\n  the load current (AC) drawn, measured using an external current\n  transformer (CT).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDevice\n  is used in electrical switchboards, in production, in distribution and\n  monitoring systems of electric power.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePrinciple\n  activities and usage\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDevice\n  is connected to the measured phase and neutral wire via terminals – this allows for measurement\n  voltage.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTaken\n  current is measured using an external current transformer CT-120, which is\n  are included in the delivery.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWires\n  secondary winding of the current transformer is connected to terminals K and L\n  on the back of the device.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAfter\n  power connection will be displayed on the screen:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eactual\n  phase voltage (in volts),\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eload\n  current (in amperes).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInstallation\n  and settings\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInstall\n  device for front panel (panel mount), cutout dimensions are 68 × 68 mm.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnect\n  CT-120 according to the diagram: the load wire is passed through the transformer and its\n  the output is connected to K and L.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAfter\n  the power supply connection of the device will automatically display the current voltage values and\n  current. (Do not use current transformers of other types or manufacturers –\n  values are calibrated in production specifically for CT-120)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  specifications\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  voltage: from 140 to 270 V alternating current (AC)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eNetwork\n  frequency: 50\/60 Hz\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplayed\n  voltage range: from 5 V to 300 V AC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMeasured\n  current range: from 1 A to 100 A (through transformer CT-120)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAccuracy\n  measurement:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003evoltage:\n  ±1 %\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ecurrent:\n  ±3 %\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay:\n  two-line, 3 digits, character height - 14 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMeasurement\n  current: via CT-120, connected to terminals K and L\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower:\n  less than 6 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  temperature: from -20 °C to +55 °C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAltitude\n  installation height: up to 2000 meters above sea level\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnection:\n  plug-in terminals\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCross-section\n  connected cable: up to 1.5 mm²\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInstallation:\n  panel, front side\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:\n115%;font-family:\" aptos mso-fareast-font-family:aptos minor-latin new=\"\" roman mso-ansi-language:cs\u003eWeight:\nup to 220 g\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102857208141,"sku":"DAV-72D","price":516.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/e74b598f2e65db8830704264ab52851c.png?v=1759322540"},{"product_id":"digitalni-panelovy-multimetr-proudu-napeti-frekvenci-vykonu-rs485","title":"Digital panel multimeter of currents, voltages, frequencies, power, RS485","description":"\u003cp\u003e\u003cstrong\u003eMultimeter - multifunctional digital panel meter, indicator of currents, voltage, frequency, and total power, with relay output and ModBus RTU by manufacturer TENSE (Turkey)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMain advantages:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRS485 Modbus RTU (1200-38400bps)\u003c\/li\u003e\n\u003cli\u003e71.5 x 61.5 custom design glass LCD\u003c\/li\u003e\n\u003cli\u003e3-phase voltage transformer and 3-phase current transformer.\u003c\/li\u003e\n\u003cli\u003eShows that V1, V2, V3, V12, V23, V31, I1, I2, I3, S1, S2, S3, F1, F2, F3\u003c\/li\u003e\n\u003cli\u003eDisplays minimum, maximum, and average values V1,V2,V3,V12,V23,V31,F1,F2,F3\u003c\/li\u003e\n\u003cli\u003eDisplays minimum, maximum, average, and required values I1,I2,I3,S1,S2,S3 High\/low voltage, current, frequency (adjustable) Phase-neutral or phase-phase protection (adjustable)\u003c\/li\u003e\n\u003cli\u003e1x relay output\u003c\/li\u003e\n\u003cli\u003eProtect voltage, current, and frequency\u003c\/li\u003e\n\u003cli\u003eDisplays the phase sequence\u003c\/li\u003e\n\u003cli\u003eYou can delete requests\u003c\/li\u003e\n\u003cli\u003eThe menu is password protected.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eTypically, this multimeter is used with current measuring transformers - 60\/5 75\/5 100\/5 150\/5 200\/5 250\/5 300\/5 400\/5 500\/5 600\/5 800\/5 1000\/5 1500\/5 or similar. Such transformers can be purchased in our e-shop,\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102857503053,"sku":"EM-07","price":2311.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/6e6b60d66cc6b72cf17be04227511157.png?v=1759322516"},{"product_id":"3-fazovy-panelovy-multimetr-proudu-napeti-frekvenci-vykonu-energie-rs485","title":"RS485 3-Phase Power Power Frequency Current Voltage Panel Multimeter","description":"\u003cp\u003e\u003cstrong\u003eThree-phase multimeter - 3-phase multifunction digital panel meter, indicator of currents, voltage, frequencies, and total power, energy kW*h and ModBus RTU by manufacturer TENSE (Turkey), panel meters.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMain advantages:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRS485 Modbus RTU (1200-38400bps)\u003c\/li\u003e\n\u003cli\u003e71.5 x 61.5 custom design glass LCD\u003c\/li\u003e\n\u003cli\u003e3-phase voltage transformer and 3-phase current transformer.\u003c\/li\u003e\n\u003cli\u003eIndicates that V1, V2, V3, V12, V23, V31, I1, I2, I3, S1, S2, S3, F1, F2, F3\u003c\/li\u003e\n\u003cli\u003eDisplays minimum, maximum, and average values V1,V2,V3,V12,V23,V31,F1,F2,F3\u003c\/li\u003e\n\u003cli\u003eDisplays minimum, maximum, average, and required values I1,I2,I3,S1,S2,S3 High\/low voltage, current, frequency (configurable) Phase-neutral or phase-phase protection (configurable)\u003c\/li\u003e\n\u003cli\u003eEnergy meter \/ Electricity meter\u003c\/li\u003e\n\u003cli\u003eProtect voltage, current, and frequency\u003c\/li\u003e\n\u003cli\u003eDisplays phase sequence\u003c\/li\u003e\n\u003cli\u003eYou can delete requests\u003c\/li\u003e\n\u003cli\u003eThe menu is password protected.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eTypically, this multimeter is used with current measuring transformers - 60\/5 75\/5 100\/5 150\/5 200\/5 250\/5 300\/5 400\/5 500\/5 600\/5 800\/5 1000\/5 1500\/5 or similar. Such transformers can be purchased in our e-shop,\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102857535821,"sku":"EM-07K","price":2450.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/5910a387f10065d5dc173de92104ec50.jpg?v=1759322506"},{"product_id":"zpozdovaci-casove-rele-12v-240v-ac-dc-1-10-100-sec-min-hod","title":"Time delay relay, 12V – 240V AC\/DC 1 \/ 10 \/ 100 sec min hour","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDetailed\n  description\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTime\n  relay with delayed activation ERV-08M up to 100 hours, with universal power supply\n  Un:12-230VAC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  delayed activation of NO contact after power is turned on (without control signal)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  time range 0.1 seconds to 100 hours\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- 1x\n  switching contact 5A\/250VAC (terminals 1,2,3)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- 2x\n  LED indicator (power, relay coil)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  universal power supply 12 - 230V AC\/DC \/ 4VA terminals A1-A2\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  DIN rail mounting\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- enclosure\n  IP20\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  dimensions 91 x 18 x 65 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eControl\n  and function description:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLED\n  indicators: ON (red LED) = relay is connected to power, OUT (green LED)\n  = lights up: output relay is activated (connected contacts 2-3), OUT (green LED) =\n  blinks: counts down the time until activation.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRotary\n  potentiometer for the range of value \"t\" from 0.1 (1%) to 10 (10=100%)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRotary\n  potentiometer for maximum time value \"TS\": A=10s, B=100s, C=10min.,\n  D=100min., E=10hrs., F=100hrs.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRelay\n  allows delayed activation of the NO contact (terminals 2-3) after power is applied (without\n  control signal).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFunction\n  switching: Time is set using the controller (TS and t). Changing the time by turning the controller\n  will manifest upon the next power connection. The output relay contains a switching\n  SPDT contact, terminal 2=COM, terminal 3=NO, terminal 1=NC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1\/ ON\n  Delay (terminals 2 - 3):\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  delayed activation after power connection Un (without control signal)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- after\n  the power connection will start the set time (t) countdown and after it elapses\n  activates the output relay Out (RLY) (connects terminals 2-3)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2\/\n  Using the NC contact as an OFF Delay (terminals 2-1)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  terminals 2 – 1 are connected even without the presence of power\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- after\n  the power connection will start the set time countdown, after which it will activate\n  output relay and disconnects terminals 1-2\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eUsage: Delays the activation of the load (e.g., fan\nit is activated only after the lighting in the restroom is turned on, the lighting turns on after the garage door is opened,\nMotor starts after the desired event, contactors, etc.). The timer will start after\nRelay activation, see photo gallery.\u003c\/span\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102857863501,"sku":"ERV-08M","price":510.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_dee76bca-a1f0-4a9d-9e80-ac8b19fdbe32.png?v=1718448436"},{"product_id":"multifunkcni-casove-rele-cas-rozsah-0-1-s-30-h-12v-240v-ac-dc","title":"Multifunctional time relay time range: 0.1 s - 30 h 12V-240V AC\/DC","description":"\u003cp\u003e\u003cstrong\u003eMultifunctional time relay (10 functions) 12V – 240V AC\/DC with 1 changeover contact.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe time relay is multifunctional, designed to control time processes in automation systems in production and in the home. This relay can be used both in industrial facilities - roasting coffee or seeds, cooking meat products, packaging \/ packaging lines, and in houses or apartments, for example, to control the fan in the toilet or the lighting in the staircase.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e10 built-in time functions cover a wide range of tasks: for example, for organizing automatic ventilation processes, opening \/ closing windows, periodically switching on heating or ventilation, for lighting or rotating advertising signs, in washing machines, bouncing control inputs, rotation - on delay, off delay, delay turning on and off at the same time, etc.\u003c\/p\u003e\u003cp\u003eIt should be noted that this time relay is also universal in terms of performance - it can work with alternating and direct current in the range from 12 to 240 volts!\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe time relay is mounted on a standard 35mm DIN rail\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBistable relay 12v 24v 48v 110v 230 AC DC\u003c\/li\u003e\n\u003cli\u003eDelayed start 12v 24v 48v 110v 230 AC DC\u003c\/li\u003e\n\u003cli\u003eDelayed return 12v 24v 48v 110v 230 AC DC\u003c\/li\u003e\n\u003cli\u003eFlasher starting with a space 12v 24v 48v 110v 230 AC DC\u003c\/li\u003e\n\u003cli\u003eDelayed start after switching on and delayed 12v 24v 48v 110v 230 AC DC\u003c\/li\u003e\n\u003cli\u003eFlasher starting with a space 12v 24v 48v 110v 230 AC DC\u003c\/li\u003e\n\u003cli\u003eDelayed start after closing and delayed return after opening the control contact (ON\/OFF DELAY) 12v 24V 48v 110v 230 AC DC\u003c\/li\u003e\n\u003cli\u003ePulse generator 12v 24v 48v 110v 230 AC DC\u003c\/li\u003e\n\u003cli\u003eDelayed return after opening the control contact (SINGLE SHOT falling edge) 12v 24V 48v 110v 230 AC DC\u003c\/li\u003e\n\u003cli\u003eDelayed return after closing the control contact (SINGLE SHOT) 12v 24V 48v 110v 230 AC DC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eUniversal time relay ERX-30 easily replaces more expensive analogs on the market - E1ZM10, MUR3, MXR1, IZT, E1ZMQ10, MFZ12-230V, ZR-67-BAT, CRM-91H, PCU-511, PCU-520, RF-520, 810.230 .00001, 83.02.0.240, PCA-511, RF-511, REV-201, REV-120, CT-MHD, THC-M1, PCU-501, PCU-530, PCM-10, 600XU-A-1-CU , BMR TRF10, CRM-91H \/UNI , MCR-MB-003, MCR-MA-003\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102858518861,"sku":"ERX-30","price":520.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file.webp?v=1718448466"},{"product_id":"automaticky-prepinac-hvezda-trojuhelnik-casove-rele-hvezda-trojuhelnik","title":"Automatic star-delta switch \/ Star-delta time relay","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRelay\n  for the star-delta starting modes (starting relay of the electric motor)\n  operating voltage 24\/220 V AC, indication of mode ON, STAR, DELTA,\n  the time setting of the STAR mode. POWER SUPPLY, ERV-YU.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIt is\n  it is known that for a soft and smooth start of the electric motor, it is necessary to first\n  turn on according to the STAR scheme and after a certain time, upon reaching the set\n  of rotation, switch the motor winding to the DELTA mode. Such a switching scheme\n  ensures a lower starting current, which increases the lifespan of the electric motor and\n  increases the stability of the entire power supply system.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSwitching\n  the STAR-DELTA modes can of course be performed using a switch, but when\n  the use of contactors (starters) and starting relay is better to manage this process\n  automation.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFor\n  the control of such contactors is offered by TENSE starting relay, or as\n  they are also called, star-delta switching relay – ERV - YU.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAfter\n  applying operating voltage to contacts A1 - A2 of relay ERV - YU, the STAR output\n  will connect to contact Faz, the STAR indicator will light up, and the countdown will begin\n  acceleration interval t1 (0.1 ... 30 s). After the acceleration interval t1, the outputs\n  STAR will disconnect, the STAR indicator will go out, and the interval will start counting down\n  pause t2 (15 ms). After the connection interval t2 has elapsed, contacts Faz and\n  TRIANGLE, the TRIANGLE indicator will light up and the starting relay is in this state,\n  as long as the alarm is connected to contacts A1 - A2.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eIf you need starters, contactors with mechanical\nblocking, separate mechanical locking, or a quality metal cabinet with\nIP65 protection, all of which you can also purchase from us at a good price from our\nwarehouse.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102858551629,"sku":"ERV-YU","price":700.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_bdd100e0-2a5f-4467-a0fe-a1ce63883fa1.png?v=1718448474"},{"product_id":"asymetricky-cyklovac-blinkr-na-zacatku-impulzu-blinkr-na-zacatku-pauzy","title":"Asymmetric cycler - Blinker at the beginning of the pulse, Blinker at the beginning of the pause","description":"\u003cp\u003e\u003cstrong\u003eTime relay - Blinker at the beginning of the pulse, Blinker at the beginning of the pause cyclic relay - symmetric \/ asymmetric cycle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eA cyclic relay or cyclic time relay is used to periodically switch on an electrical load (such as lights, fans, etc.) or to supply control signals in automatic monitoring or control systems (such as turning on an emergency flashing light or an audible signal). This cyclic timer can be useful for organizing automatic ventilation processes, opening and closing windows, periodically switching on heating or ventilation, for lighting or rotating advertising signs.\u003c\/p\u003e\u003cp\u003eIf you configure the relay so that its turn-on and pause times are symmetrical, it can be used, for example, to gradually turn on some electrical appliances in case of current \/ power limitation (heating elements, heat generators). The presence of a switching output contact allows the cycle to be started either with a pulse or with a pause.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003etime relay - cycler with independently adjustable time of switching on and off the output\u003c\/li\u003e\n\u003cli\u003eused for regular room ventilation, cyclic drying of humidity, lighting control, circulation pumps, illuminated advertising, etc.\u003c\/li\u003e\n\u003cli\u003eThe time relay is mounted on a standard 35mm DIN rail\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102858584397,"sku":"ERV-09","price":858.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_3f291aa9-7ac7-452f-9a4a-50a16378abcb.png?v=1718448483"},{"product_id":"asymetricky-cyklovac-casove-cyklicke-rele-se-dvema-displeji-12vdc-230vac","title":"Asymmetric cycler \/ Time cyclic relay with two displays -12VDC,230VAC","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCyclic\n  ERV-09D relay, manufacturer Tense (Turkey)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIndicator\n  the ERV-09D relay is intended for use in places (manufacturing, residential buildings, factories\n  etc.), where dual (On-Off) control is required.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e230 V\n  AC or 12 V DC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperation:\n  1 s - 99 min (adjustable)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eStandby\n  mode: 1 s - 99 min (adjustable)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay:\n  the value is displayed when setting the time and counting down the set time.\n  If the operating time is set in minutes, the dot on the display will be on the right\n  blinking while the device is counting down.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIndication\n  ON is reserved for operating time and OFF indication is reserved for\n  standby time.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  specification\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  voltage (A1-A2) 100–240 V AC, 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  voltage (A2-A3) 12 V DC (A2(-), A3(+))\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  frequency 50\/60 Hz. Operating power: \u0026lt;6 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  temperature: -20 °C.....+55 °C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTime\n  interval: 0.1 s - 99 min.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay:\n  2x2 LED display, 1 LED.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eType\n  connection: DIN rail mounting. Weight: \u0026lt;80 g. Contact: 5 A, 250 V AC,\n  resistive load\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eOperating altitude: \u0026lt;2000 m. Cable diameter:\n2.5 mm²\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102858649933,"sku":"ERV-09D","price":1097.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_6c1404d4-0120-4dc6-aa1e-9986092768a6.png?v=1718448489"},{"product_id":"asymetricky-cyklovac-2-2-led-displej-pro-montaz-na-panel-dvere-230vac","title":"Asymmetric cycler 2x2 LED display for panel\/door mounting 230VAC","description":"\u003cp\u003e\u003cstrong\u003eAsymmetric cycler \/ Time cyclic relay 2x2 LED display for panel\/door mounting 230VAC - Blinker at the beginning of the pulse, Blinker at the beginning of the pause cyclic relay - symmetric \/ asymmetric cycle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eA cyclic relay or cyclic time relay is used to periodically switch on an electrical load (such as lights, fans, etc.) or to supply control signals in automatic monitoring or control systems (such as turning on an emergency flashing light or an audible signal). This cyclic timer can be useful for organizing automatic ventilation processes, opening and closing windows, periodically switching on heating or ventilation, for lighting or rotating advertising signs.\u003c\/p\u003e\u003cp\u003eIf you configure the relay so that its turn-on and pause times are symmetrical, it can be used, for example, to gradually turn on some electrical appliances in case of current \/ power limitation (heating elements, heat generators). The presence of a switching output contact allows the cycle to be started either with a pulse or with a pause.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102858682701,"sku":"DFR-72","price":1114.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_bddc6dfa-a2a4-4e8b-96f4-86facf3fbc85.png?v=1718448497"},{"product_id":"casove-inverzni-reverzni-cyklicke-rele-230v-ac","title":"Time inverse reverse cyclic relay 230V AC","description":"\u003cp\u003e\u003cstrong\u003eTime inverse reverse cyclic relay - \"left - right\", \"up - down\", \"forward - backward\"\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe device is intended for cyclic switching of two independent loads in \"left-right\", \"up-down\", \"forward-backward\" modes or performing the reverse mode of electric motor operation with a delay between switching on (dishwashers and washing machines). You can select a time between 0.1 seconds and 100 minutes for both \"Ton\" and \"Toff\" modes.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe time relay is mounted on a standard 35mm DIN rail\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102858715469,"sku":"ERS-07","price":1003.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_33504a7e-b489-4b58-95c0-7ae8661dc501.png?v=1718448506"},{"product_id":"casovac-na-din-listu-digitalni-24h-230-v-ac-16a-250v-4000va-astronomicke-spinace","title":"DIN rail timer digital 24h 230 V\/AC 16A\/250V\/4000VA astronomical switch","description":"\u003cp\u003e\u003cstrong\u003eAstronomical - Day timer \/ timer on DIN rail digital 24h 230 V\/AC 16 A\/250 V 4000VA\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eIt is used to set the on and off time of electrical appliances such as water heaters, lighting, motors, pumps, etc.\u003c\/p\u003e\u003cp\u003eThis 24-hour sleep timer has the function of setting the time, supports editing the current time, supports changing the hour and minute settings.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReal time clock\u003c\/li\u003e\n\u003cli\u003ePower reserve - 5 years\u003c\/li\u003e\n\u003cli\u003eNumber of programs: 48\/72\/96\/144\/288\u003c\/li\u003e\n\u003cli\u003eSwitching step: 5\/10\/15\/20\/30 minutes\u003c\/li\u003e\n\u003cli\u003eSwitching time: 1 - 99 seconds, full step\u003c\/li\u003e\n\u003cli\u003e16A, 250VAC, 4000VA (AC1)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe time relay is mounted on a standard 35mm DIN rail\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102858781005,"sku":"TTR-10","price":1003.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_940675e1-bc28-4bde-bce5-8dab8aab1e74.png?v=1718448510"},{"product_id":"casovac-casove-rele-se-zpozdenim-zapnuti-vypnuti-one-shot-rele","title":"Timer \/ Time relay with on \/ off delay \/ One Shot relay","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDetailed\n  description\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDigital\n  time relay DRV-10 with a display, with delayed activation and delayed deactivation up to\n  99 minutes, with a control signal\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDRV-10\n  is a digital time relay triggered by a signal at input TR with a delay in activation\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003esky\n  with a shutdown delay adjustable up to 99 minutes, suitable for use everywhere\n  where time-dependent control of devices is required.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(see\n  detailed description and photo gallery)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  time range 1 second to 99 minutes\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- 1x\n  switching contact 5A\/250VAC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- 2x\n  LED indicator (power, relay coil)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  power supply 230V AC\/DC \/ 4VA terminals A1-A2\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- or\n  power supply 24VAC\/VDC \/ terminals A2-A3\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  DIN rail mounting\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- protection\n  IP20\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  dimensions 90 x 23 x 58 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUsage:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDelays\n  load activation (toilet fan, lighting, motor starts, contactors, etc.).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCounting\n  the time will start after the relay is activated, see the photo gallery.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDescription\n  actions:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eON Delay\n  – delayed activation\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  delayed activation of the NO relay contact after the time counted from the rising\n  the rising edge of the control signal at the terminal (TR)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- on\n  see the countdown timer on the display (value in seconds or minutes) until\n  activation (waiting time)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- relay\n  remains on until the next rising edge of the control signal at terminal 6 (TRG)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOFF Delay\n  – delayed shutdown\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  immediate activation of the NO relay contact after the rising edge of the control signal at the terminal\n  (TR)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- relay\n  remains on during the time set via the controllers (duration in the on state\n  (state)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003e- see the countdown timer on the display until shutdown\n(value in seconds or minutes)\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102860419405,"sku":"DRV-10","price":891.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_d29b9eff-66ef-40df-88a4-617b1cd83cf5.png?v=1718448517"},{"product_id":"pocitadlo-provoznich-hodin-s-lcd-displejem-24ac-dc-230vac","title":"Hour meter with LCD display 24AC\/DC 230VAC","description":"\u003cp\u003e\u003cstrong\u003eOperating hours counter with LCD display digital panel 24AC\/DC 230VAC\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCounter range: 99999h59m\u003c\/li\u003e\n\u003cli\u003eReset button (HM-48D)\u003c\/li\u003e\n\u003cli\u003eOperating voltage (input signal) 24 or 230 volts\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Again \/ Yes","offer_id":49102860517709,"sku":"HM-48D","price":780.0,"currency_code":"CZK","in_stock":false},{"title":"Yes \/ No","offer_id":49102860550477,"sku":"HM-48","price":780.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/0f647d092a566b4d19aad43efe3036f2.png?v=1764590415"},{"product_id":"pocitadlo-provoznich-hodin-digitalni-s-lcd-displejem-230vac","title":"Digital operating hours counter with LCD display 230VAC","description":"\u003cp\u003e\u003cstrong\u003eOperating hours counter with LCD display 230VAC with digital reset button.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCounter range: 99999h59m\u003c\/li\u003e\n\u003cli\u003eReset\u003c\/li\u003e\n\u003cli\u003eOperating voltage (input signal) 230 volts\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"FROM","offer_id":49102860616013,"sku":"DHM-DIN","price":780.0,"currency_code":"CZK","in_stock":true},{"title":"To the panel","offer_id":49102860648781,"sku":"DHM-48","price":780.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_82b4c9eb-82ac-4501-b424-4372cbd391c5.png?v=1718448503"},{"product_id":"elektronicke-pocitadlo-pulzu-pocitadlo-impulzov","title":"Electronic pulse counter \/ Pulse counter","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDetailed\n  description\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCounter\n  impulses for panel DS-48\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e(2x\n  4-digit display: 1x counter, 1x target value)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eGeneral\n  specifications of the pulse counter DS-48:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x\n  4-digit display, 1x preset value,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1x\n  output relay OUT,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ecounter\n  hours\/down\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCounts\n  signals from mechanical switches, inductive PNP\/NPN proximity sensors and\n  of inputs from the incremental encoder.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eProtection\n  with a password.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOptional\n  input frequency: 20, 50, 2500, 7500 Hz\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCalibration\n  constant: 0,001.....9,999\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOptional\n  decimal point: 0, 0,0, 0,00, 0,000\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOptions\n  combination of functions: 7 input functions \/ 9 output functions:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  counting,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  counting down,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  counting\/counting from two inputs simultaneously,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e- pause\n  in counting\/counting controlled by the second input,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  input negation controlled by the second input,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  counting\/subtracting from the rising edge \/ falling edge \/ both edges simultaneously,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e-\n  counting on the rising edge \/ subtracting on the falling edge \/ negation function with the second\n  input\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAdjustable\n  \"OFFSET\" of the calculated value\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOUTPUT\n  relay: will turn on when the value is reached and will hold until RESET or a pulse in\n  range of 0.1.....999.9 seconds\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRemembers\n  the value of the pulse count and the state of the output relay OUT at the last failure\n  power and can be restored after the first power on.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRESET\n  by the button on the front panel or by a signal at the RESET terminal (12).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMemory\n  EEPROM for storing settings.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eNotes\n  for installation:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUse\n  shielded and twisted signal cable and ground the shielding. Keep all\n  signal cables away from circuit breakers, inductive loads, devices\/cables that\n  emit electrical noise, and power cables.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePrevent\n  environmental influences, such as humidity, vibration, pollution, and high\/low\n  temperature.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOn\n  the device's network\/power input, use a fuse (F250mA 250VAC).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFor\n  for power use a suitable cable. During installation, adhere to safety\n  regulations.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBefore\n  preferably use the option (Input = Phs1), select (Frequency = 20)\n  for counting pulses of the mechanical ON-OFF switch,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eselect\n  the optimal minimum input frequency that suits your application.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePre\n  Input = 1u2u, 1u2d, Phs2; the frequency of the input signal must be a maximum of ½\n  selected input frequency, if both inputs are used.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePre\n  Inpt = Phs4; the frequency of the input signal must not exceed 1\/4 of the selected\n  input frequency, if both inputs are used.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  parameters:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDimensions\n  \/ \u003c\/span\u003e\u003cspan lang=\"CS\"\u003e​​cutout: 48x48x96 mm \/ 44x44 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay:\n  2x4-digit 7-segment LED display.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eNumber\n  inputs: 2 x (Max: 7500 Hz, 5-30 V)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eType\n  input: mechanical switch, inductive PNP\/NPN sensor, encoder output\n  NPN\/PNP\/totem-pole\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInput\n  frequency: 20, 50, 2500, 7500 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSelection\n  NPN sensor: Before the NPN, connect terminal \"npn select\" (8) to terminal \"+12V\" (9) and\n  then select the NPN sensor connected to input Cp1(10) and Cp2 (11).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReset\n  the input is always PNP.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBefore\n  totem or PNP sensors will not connect with 'npn select'.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReset\n  signal: terminal (12), minimum 10 ms, + signal (only PNP) (5.....30 V)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower supply\n  voltage: 100...240 V AC, 50-60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConsumption\n  power: \u003c 8 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOutput\n  (OUT):\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1x relay\n  SPDT 250VAC, 2A, resistive load, terminals 4=COM, 3=NO, 5=NC,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1x\n  SSR control - NPN, 30V, max. 100mA, terminal 13=SSout, 14=GND\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower supply\n  sensor: terminal (9) 12 VDC, 50 mA (max.), unregulated\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConversion\n  temperature: -20°C ... +55°C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eAltitude of the supervisor: \u003c2000m\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102860681549,"sku":"DS-48","price":1290.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_725ef8bb-f534-4b7c-8a82-c88145b0b63c.png?v=1718448511"},{"product_id":"elektronicke-pocitadlo-pulzu-pocitadlo-impulzov-1","title":"Electronic pulse counter \/ Pulse counter + -","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDetailed\n  description\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eGeneral\n  specification of the pulse counter DS-72A:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x 6\n  local display,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x\n  PRESET value,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x OUT\n  output relays,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x\n  SSout for controlling SSR relays.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCounts\n  signals from mechanical switches, limit switches, inductive sensors\n  approaching PNP\/NPN and inputs from the incremental encoder.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCounting\n  up\/down.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eProtection\n  heslem.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOptional\n  input frequency: 20, 50, 2500, 7500 Hz\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCalibration\n  constant: 0.00001.....9.99999\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOptional\n  decimal point: 0 \/ 0.0 \/ 0.00 \/ 0.000\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOptions\n  function combinations: 7 input functions \/ 10 output functions:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eaddition,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003esubtraction,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eaddition\/subtraction\n  from two inputs simultaneously,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003epause in\n  counting\/subtraction controlled by the second input,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003enegation\n  input controlled by the second input,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eaddition\/subtraction\n  from the leading edge \/ falling edge \/ both edges simultaneously,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eaddition\n  leading edge \/ falling edge countdown \/ negation function by the second\n  input.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAdjustable\n  \"OFFSET\" calculated value.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePRESET1\n  with the option of absolute\/relative values.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOUT 2x\n  relay: turned on after reaching the value and held until RESET, or pulse in the range\n  0.1.....999.9 seconds.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRemembers\n  the value of the number of pulses and the state of the output relay OUT at the last power failure\n  power and can be restored after the first power on again.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRESET\n  be done via the button on the front panel or a signal to terminal RESET(17).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCan\n  to display preset ½ values.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMemory\n  EEPROM for storing settings.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  properties:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDimensions\n  \/ \u003c\/span\u003e\u003cspan lang=\"CS\"\u003e​​opening: 72x72x94 mm \/ 67x67 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay:\n  2x 6-digit 7-segment LED display.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIndicator LED:\n  5x: OUT1, OUT2, Finger1, Finger2, Batch\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInputs:\n  2x (Max: 7500 Hz, 5-30 V)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSelection\n  NPN: connect the \"npn select\" terminal (13) to the \"+12V\" terminal (14) for connection\n  NPN sensors connected to input Cp1(15) and Cp2 (16).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReset\n  input is always PNP.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFor\n  totem-pole encoder or PNP type sensors will have \"npn select\" not connected.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTypes\n  inputs: mechanical switch, inductive sensor PNP\/NPN encoder output\n  NPN\/PNP\/totem-pole.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInput\n  frequency: 20, 50, 2500, 7500 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReset\n  signal: RESET terminal (17), at least 10 ms, + signal (only PNP) (5...30 V).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOutputs\n  (OUT):\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2x relay\n  SPDT 250VAC, 2A, resistive load,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOUT1:\n  terminals 6=COM, 5=NO, 7=NC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOUT2:\n  terminals 9=COM, 8=NO, 10=NC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSSout\n  2x control SSR - NPN, 30V, 100mA max., terminal 18=SSout1, 19=SSout2, 20=GND\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower\n  sensors: terminal (14) 12 VDC, 50 mA (max.), unregulated.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePower supply\n  voltage: 100...240VAC, 50-60Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConsumption\n  power: \u003c 8 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  temperature: -20°C ... +55°C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAbove sea level\n  height: \u003c2000m\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eNotes\n  for installation:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUse\n  shielded and twisted signal cables and shielding connect to ground. Maintain\n  all signal cables outside of circuit breakers, inductive loads, outside of devices\/cables\n  radiating electrical noise and power cables. Take preventive measures\n  against environmental influences such as humidity, vibration, pollution, and high\/low\n  installation temperature.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUse\n  the fuse (F250mA 250VAC) on the device's mains\/power input.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTo\n  for power supply use appropriate cables. During installation, follow safety\n  regulations.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePrefer\n  the use of the option (Inpt = Phs1) for encoders,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSelect\n  (Freq = 20) for counting pulses of the mechanical ON-OFF switch.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAlways\n  select the minimum input frequency option that suits your application.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFor\n  Inpt = 1u2u, 1u2d, Phs2; the frequency of the input signal must be at most ½\n  the selected input frequency options, if both inputs are used.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eFor Inpt = Phs4; the frequency of the input signal must be\nat most 1\/4 of the selected input frequency option, if both inputs are used.\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102860747085,"sku":"DS-72A","price":1893.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_c265539c-fc00-455a-be7c-e9e305fd8d80.png?v=1718448517"},{"product_id":"regulator-termostat-teploty-na-din-listu-zap-vyp-on-off-spinace-teploty","title":"Temperature regulator thermostat on DIN rail ON-OFF ON - OFF - temperature switches","description":"\u003cp\u003e\u003cstrong\u003e2-point temperature controller \/ thermostat for mounting on a rail with an external sensor. ON-OFF ON- OFF control mode, measurement range -30ºC ...+150ºC (made in Turkey, TENSE) DT-321DIN\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThermostat regulator with external sensor\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe temperature controller DT-321DIN is characterized by its individual usability and is used to control heating or cooling devices. Alternatively, the DT-321DIN can also simply serve as a reading device.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eRegulation and monitoring of thermal processes of heating, air conditioning and ventilation systems, automation of buildings, industrial plants.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eSensor type: NTC\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRelay outputs OUT and ALARM (NO+NC) 250VAC, 2A\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOptional heating and cooling function\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003eHysteresis\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAdjustable ON\/OFF timers for OUT output in case of sensor failure\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003eCompression protection thanks to adjustable switch-off times\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eUpper and lower limits for SET and ALARM settings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAdjustable separate hysteresis for SET and ALARM settings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTurn-on delay for OUT in cooling mode\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eEEPROM memory for saving settings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePassword protection\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHigh accuracy\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eScope of delivery:\u003c\/p\u003e\u003cp\u003e1x temperature controller DT-321DIN\u003cbr\u003e1x NTC (sensor)\u003cbr\u003e1x user manual (English)\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eYou can use this simple temperature controller with the three types of sensors presented on our website:\u003c\/p\u003e\u003col\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pelek.cz\/product-page\/teplotn%C3%AD-%C4%8Didlo-termo%C4%8Dl%C3%A1nek-teplotn%C3%AD-%C4%8Dl%C3%A1nek-ntc-typ\" target=\"_blank\"\u003ereference to type 1: -30°C to 105°C\u003c\/a\u003e - SKU: NTC-105 (included in delivery)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pelek.cz\/product-page\/teplotn%C3%AD-%C4%8Didlo-termo%C4%8Dl%C3%A1nek-teplotn%C3%AD-%C4%8Dl%C3%A1nek-ntc-typ\" target=\"_blank\"\u003ereference to type 2: -30°C to 150°C\u003c\/a\u003e - SKU: NTC-150\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.pelek.cz\/product-page\/teplotn%C3%AD-%C4%8Didlo-termo%C4%8Dl%C3%A1nek-teplotn%C3%AD-%C4%8Dl%C3%A1nek-ntc-typ\" target=\"_blank\"\u003elink to type 3: -30°C to 150°C (with nut and thread)\u003c\/a\u003e - SKU: NTC-S-150\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eFeatures:\u003c\/p\u003e\u003cp\u003eSupply voltage: 100 to 240 V AC, 50\/60 Hz\u003cbr\u003ePower consumption: \u003c6 VA\u003cbr\u003eSensor type: NTC\u003cbr\u003eTemperature measurement range: - 30 °C to + 150 °C\u003cbr\u003eResolution: +\/- 1 °C\u003cbr\u003eMeasurement accuracy: +\/- 3% (°C), in the entire measurement range\u003cbr\u003eOUT Output: Relay (NO + NC), 250V AC, 2A\u003cbr\u003eALARM output: Relay (NO + NC), 250V AC, 2A\u003cbr\u003eOperating temperature: 0°C to 50°C\u003cbr\u003eHeating\/Cooling: Ht (Heating), Cl (Cooling); optional\u003cbr\u003eFront panel cutout: 66 x 36 mm\u003cbr\u003eDisplay: 3-digit - 7-segment\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eProduct type: temperature measuring device\u003cbr\u003eProtection class: IP00\u003cbr\u003eBrand: Tense\u003cbr\u003eCountry and region of production: Türkiye\u003cbr\u003eSupply voltage: 100V - 240V ~\u003cbr\u003eConnection type: screw terminals\u003cbr\u003eMounting: DIN rail\u003cbr\u003eTemperature measurement range: -30...+150°C\u003cbr\u003eSwitching output: Temperature relay (NO + NC), 250VAC, 2A, ohmic load\u003cbr\u003eSensor type: NTC sensor\u003cbr\u003eShipping weight: 0.12 kg\u003cbr\u003eItem weight: 0.10 kg\u003cbr\u003eDimensions (length x width x height): 8.50 x 7.80 x 36.00 cm\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102861041997,"sku":"DT-321DIN","price":791.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/0772c2f8fc0cee58f94526f2944f33b8.png?v=1776422425"},{"product_id":"regulator-termostat-teploty-pro-montaz-do-panelu-on-off-s-externim-cidlem","title":"Thermostat temperature regulator for mounting in an ON - OFF panel with an external sensor","description":"\u003cp\u003e\u003cstrong\u003eThermostat \/ 2-point temperature controller for panel mounting ON-OFF control mode, \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ethermostat with external sensor, measurement range -30ºC ...+150ºC, resolution \/ step 1ºC (made in Turkey, TENSE) DT-321\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eControl and monitoring of thermal processes in heating, air conditioning, and ventilation systems, building automation, industrial plants.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eSensor type: NTC\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRelay outputs OUT and ALARM (NO+NC) 250VAC, 2A\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOptional heating and cooling function\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003eHysteresis\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAdjustable ON\/OFF timers for OUT output in case of sensor failure\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003eProtection against compression due to adjustable off times\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eUpper and lower limits for SET and ALARM settings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAdjustable independent hysteresis for SET and ALARM settings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTurn-on delay for OUT in cooling mode\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eEEPROM memory for storing settings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePassword protection\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHigh accuracy\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eYou can use this simple temperature controller with three types of sensors presented on our website\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102861205837,"sku":"DT-321","price":791.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/ca9011c0c7ff3eb672cf26d07f5a537a.png?v=1776422412"},{"product_id":"regulator-termostat-teploty-pro-montaz-do-panelu-on-off-s-externim-cidlem-1","title":"Thermostat temperature regulator for mounting in an ON - OFF panel with an external sensor","description":"\u003cp\u003e\u003cstrong\u003eThermostat \/ 2-point temperature controller for panel mounting ON-OFF\/ ON-OFF control mode, measurement range -19.9 °C – +99.9 °C, resolution \/ step 0.1ºC (made in Turkey, TENSE) DT-322\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eRegulation and monitoring of thermal processes of heating, air conditioning and ventilation systems, automation of buildings, industrial plants.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eSensor type: NTC\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRelay outputs OUT and ALARM (NO+NC) 250VAC, 2A\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOptional heating and cooling function\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003eHysteresis\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAdjustable ON\/OFF timers for OUT output in case of sensor failure\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003eCompression protection thanks to adjustable switch-off times\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eUpper and lower limits for SET and ALARM settings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAdjustable separate hysteresis for SET and ALARM settings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTurn-on delay for OUT in cooling mode\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eEEPROM memory for saving settings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePassword protection\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHigh accuracy\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102861631821,"sku":"DT-322","price":791.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_ee130e0b-0ed9-4c76-bc8c-cef60eac05cb.png?v=1718448545"},{"product_id":"teplotni-cidlo-termoclanek-teplotni-clanek-ntc-typ","title":"Temperature sensor thermocouple temperature cell NTC type","description":"\u003cp\u003e\u003cstrong\u003eTemperature sensor \/ thermocouple type temperature sensor NTC,\u003c\/strong\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"-30°C do 105°C","offer_id":49102861697357,"sku":"NTC-105","price":101.0,"currency_code":"CZK","in_stock":false},{"title":"-30°C do 150°C","offer_id":49102861730125,"sku":"NTC-150","price":223.0,"currency_code":"CZK","in_stock":true},{"title":"-30°C to 150°C (with nut and thread)","offer_id":49102861762893,"sku":"NTC-S-150","price":287.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_050a61d6-f833-4aed-8aff-50694199a074.webp?v=1718448529"},{"product_id":"vysoka-presnost-regulator-teploty-pro-montaz-do-panelu-on-off-az-600ºc","title":"High precision temperature controller for panel mounting ON - OFF up to 600ºC","description":"\u003cp\u003e\u003cstrong\u003eThermostat \/ 2-point temperature controller for panel mounting ON\/OFF ON\/OFF control mode, measurement range 0°C ... +600°C, resolution \/ step 1ºC (made in Turkey, TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eControl and monitoring of thermal processes in heating, air conditioning, and ventilation systems, building automation, industrial plants.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eSensor type: J type, Fe-Const, T\/C\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRelay outputs OUT (NO+NC) 250VAC, 2A\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003eHysteresis\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eEEPROM memory for storing settings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePassword protection\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHigh accuracy: %0.3\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003ePlease remember to order our temperature sensors - type J thermocouple Fe-Const (metric 6\/8) with a temperature measurement range of: -100 °C – +600 °C. It can be with a cable 1 m, 1.5 m, 2 m, 2.5 m, 3 m, 4 m, and 5 meters long.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"36mm x 78mm","offer_id":49102861828429,"sku":"DT-36E","price":891.0,"currency_code":"CZK","in_stock":false},{"title":"48mm x 48mm","offer_id":49102861893965,"sku":"DT-48E","price":902.0,"currency_code":"CZK","in_stock":false},{"title":"73mm x 73mm","offer_id":49102861926733,"sku":"DT-72E","price":955.0,"currency_code":"CZK","in_stock":false},{"title":"97mm x 97mm","offer_id":49102861959501,"sku":"DT-96E","price":1008.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_9fc97ebb-a3a2-4d6e-8750-01c9eb81700b.png?v=1765891272"},{"product_id":"mikroprocesorovy-regulator-teploty-pid-s-casovacem-pro-montaz-do-panelu-1750-c","title":"Microprocessor PID temperature controller with timer for panel mounting 1750°C","description":"\u003cp\u003e\u003cstrong\u003ePID temperature controller for panel mounting with built-in timer, measurement range -100°C ... +1750°C, resolution \/ step 0.1ºC (made in Turkey, TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eControl and monitoring of thermal processes in heating, air conditioning, and ventilation systems, building automation, industrial plants.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe temperature controller operates using on\/off or PID control. The controller offers self-optimization, which prevents overshooting of the process value.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eAutomatic tuning of PID parameters\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003eSensor type: T\/C (J,K,T,S,R), Pt100\u003c\/li\u003e\n\u003cli\u003eOptional control type: P, PI, PD, PID, or ON-OFF\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAutomatic removal of 'overshoot' in PID mode\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003eAnti-windup\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTurn-on delay for OUT in cooling mode\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePassword protection\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eEEPROM memory for storing settings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRelay outputs OUT and ALARM (NO+NC) 250VAC, 2A (ALARM only ON for DTZ-48)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe measurement range depends on the sensor and can be set using the buttons on the temperature controller.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe display of the temperature controller is a high-contrast display that can be read accurately even under poor conditions. In addition to the control output, the temperature controller has an additional alarm relay that closes a potential-free contact when the value is exceeded or not reached.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003ePlease remember to order our temperature sensors - type J Fe-Const thermocouple (metric 6\/8) with a temperature measurement range of: -100 °C – +600 °C. It can be with a cable 1 m, 1.5 m, 2 m, 2.5 m, 3 m, 4 m, and 5 meters long.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"48mm x 48mm","offer_id":49102862287181,"sku":"DTZ-48","price":1448.0,"currency_code":"CZK","in_stock":false},{"title":"72mm x 72mm","offer_id":49102862352717,"sku":"DTZ-72","price":1432.0,"currency_code":"CZK","in_stock":false},{"title":"96mm x 96mm","offer_id":49102862385485,"sku":"DTZ-96","price":1485.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_cde0a419-ae35-444e-b492-236e049f5d1e.png?v=1718448599"},{"product_id":"dc-ac-elektronicke-jednofazove-polovodicove-rele-ssr-spinaci-kontakt-25a-40a","title":"DC-AC electronic single-phase solid state relay SSR switching contact 25A, 40A","description":"\u003cp\u003e\u003cstrong\u003eDC-AC single-phase electronic solid state relay SSR switching contact 25A, 40A, for mounting on 35mm DIN rail. \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eDC input 3-32 VDC, AC output circuit 24-380 VAC (thyristors), high number of switching cycles (without burning of contact material), noiseless switching and low excitation power.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"25A","offer_id":49102862418253,"sku":"IG3PA-4825D","price":724.0,"currency_code":"CZK","in_stock":true},{"title":"40A","offer_id":49102862451021,"sku":"IG3PA-4840D","price":390.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_c3145636-e4e6-4918-8fbb-a28bf2ca8161.jpg?v=1718448611"},{"product_id":"regulator-jaloveho-vykonu-12-urovnovy-s-led-obrazovko","title":"12-level reactive power regulator with LED screen","description":"\u003cp\u003e\u003cstrong\u003e12 steps Single phase connection Power factor controller for power factor control in networks with balanced load (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe RGM-12S reactive power control relay is designed to reduce inductive powers that do not use loads but are drawn from the grid. If inductive reactive power is taken from the network, it interferes by activating the capacitors of the respective values. In this way, it tries to bring the value of Cos fi to the desired level.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e7 Various power factor compensation programs\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eManual power factor compensation programs\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eIt can only compensate induction systems\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAutomatic step measurement\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eStepper drive, release and discharge times are adjustable\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHarmonic voltage and current alarm values ​​adjustable\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eOvercompensation and undercompensation alarm values ​​can be set\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage, harmonic voltage\/current, over and under compensation alarm output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage, current and frequency values ​​can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eActive power, reactive power and apparent power values ​​can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eUp to 15th harmonic THD-I can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eUp to 15th harmonic THD-V can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eThe cosine value can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eThe power factor value can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eAutomatic fan output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eEqual aging in steps (in some compensation programs)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102866776397,"sku":"RGM-12S","price":4221.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/0764c9ac7c5fc216c12aa893b22e4e13.webp?v=1761304335"},{"product_id":"rgt-12svc-regulator-jaloveho-vykonu-12-urovnovy-tcr-s-rs485-modbus-rtu","title":"RGT-12SVC - Reactive power regulator 12 levels +TCR with RS485 ModBus RTU","description":"\u003cp\u003e\u003cstrong\u003e12 steps + TCR Power factor controller with 2.9 inch graphic LCD display and RS-485 (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe reactive power regulator \u003cstrong\u003eRGT-12SVC (TENSE)\u003c\/strong\u003e is a fully automatic device for optimal switching of compensation stages.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eDigital processing of the values ​​measured by the controller ensures high accuracy of the evaluation of the effective value of voltage, current and power factor. \u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe installation of the device is fully automatic - the controller itself determines the size of the individual connected compensation stages. These parameters can also be entered directly manually.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe regulator switches on and off the compensation stages so that the regulation of the reactive power takes place with a minimum number of switchings. At the same time, the regulator takes into account the uniform load of the individual stages and preferentially switches those which have been disconnected for the longest time and for which the residual charge is minimal. During regulation, continuous control of compensation stages is carried out simultaneously - outages and changes in values ​​are detected, temporarily disabled stages are periodically tested and, if necessary, put back into the regulation process.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eGenerator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHit, discharge and settling times can be set\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRemote communication with RS485 (RS485 ModBus RTU)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eA single-phase, two-phase and three-phase capacitor and shunt reactor can be connected\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHarmonic voltage and current can be observed up to the 31st harmonic\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTotal energy can be monitored (import\/export)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eThe THD-V and THD-I values ​​of each phase can be observed\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePower analysis generation (20 samples 9999 min.) - for capacitor selection\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102866841933,"sku":"RGT-12(SVC)","price":6570.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_3a615070-54d4-45c1-baf2-1ec8ced29737.png?v=1718448650"},{"product_id":"rgt-12e-regulator-jaloveho-vykonu-12-urovnovy-tcr","title":"RGT-12E - Reactive power regulator 12 levels +TCR","description":"\u003cp\u003e\u003cstrong\u003e12 steps + TCR Power factor controller with 2.9 inch graphic LCD display (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003eRGT-12E (TENSE)\u003c\/strong\u003e reactive power regulator is a fully automatic device for optimal switching of compensation stages.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eDigital processing of the values ​​measured by the controller ensures high accuracy of the evaluation of the effective value of voltage, current and power factor. \u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe installation of the device is fully automatic - the controller itself determines the size of the individual connected compensation stages. These parameters can also be entered directly manually.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe regulator switches on and off the compensation stages so that the regulation of the reactive power takes place with a minimum number of switchings. At the same time, the regulator takes into account the uniform load of the individual stages and preferentially switches those which have been disconnected for the longest time and for which the residual charge is minimal. During regulation, continuous control of compensation stages is carried out simultaneously - outages and changes in values ​​are detected, temporarily disabled stages are periodically tested and, if necessary, put back into the regulation process.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eGenerator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHit, discharge and settling times can be set\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eA single-phase, two-phase and three-phase capacitor and shunt reactor can be connected\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHarmonic voltage and current can be observed up to the 31st harmonic\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTotal energy can be monitored (import\/export)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eThe THD-V and THD-I values ​​of each phase can be observed\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePower analysis generation (20 samples 9999 min.) - for capacitor selection\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102867890509,"sku":"RGT-12E","price":5512.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/a1a8c8ce294759ea0cac4554bed17012.png?v=1761302135"},{"product_id":"rgt-mt18-regulator-jaloveho-vykonu-18-urovnovy-tcr-s-rs485-modbus","title":"RGT-MT18 - Reactive power regulator 18 levels +TCR with RS485 ModBus","description":"\u003cp\u003e\u003cstrong\u003e18 steps + TCR Power factor controller for symmetrical \/ asymmetrical networks with 5 inch touch screen and RS-485 (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eReactive power control relays are designed to reduce reactive power (inductive and capacitive) that is not used by the load and is drawn from the grid. If inductive power is taken from the network, it intervenes by taking the capacitor at a suitable value. If the capacitive power is taken from the network, it intervenes by removing the shunt choke at a suitable value. In this way, it tries to reduce the inductive\/active and capacitive\/active speeds of the system. It is designed to provide more reasonable compensation for unbalanced inductive and capacitive systems with the RGT-MT18 TCR step \u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eGenerator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage, harmonic current\/voltage, inductive and capacitive alarm output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHit, discharge and settling times can be set\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRemote communication with RS485 (RS485 ModBus RTU)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eA single-phase, two-phase and three-phase capacitor and shunt reactor can be connected\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHarmonic voltage and current can be observed up to the 61st harmonic\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTotal energy can be monitored (import\/export)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eThe THD-V and THD-I values ​​of each phase can be observed\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePower analysis generation (20 samples 9999 min.) - for capacitor selection\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTemperature alarm output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eDemand registration (active and reactive and apparent power and current demand)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eThe minimum, maximum and average current and voltage values ​​of each phase can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eActual date and time\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102867923277,"sku":"RGT-MT18","price":8352.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/29021cc84c53911daf6559abe27a8950.png?v=1761302508"},{"product_id":"reverzni-vackovy-spinac-reverzacni-otocny-prepinac-1-0-1-3-polu-10-120a","title":"Reversing cam switch \/ Reversing rotary switch 1-0-1, 3 poles, 10-120A","description":"\u003cp\u003e\u003cstrong\u003eReversing rotary switch 1-0-1, 3 poles, 10-120A, YPT304 manufacturer OPAŞ (Turkey)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eReversing cam rotary switch designed to change the direction of rotation of electric motors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage switches\u003c\/strong\u003e are intended for manual switching of low voltage circuits. They are used for creating main and control circuits, turning on and off electric motors and other low-power devices. The advantages of switches in this series are compact dimensions, electrical and mechanical resistance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign: Joint\u003c\/li\u003e\n\u003cli\u003eDevice type: Rotary switch\u003c\/li\u003e\n\u003cli\u003eSwitching scheme: 1-0-1 9 (reversing)\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 3\u003c\/li\u003e\n\u003cli\u003eType: Built-in\u003c\/li\u003e\n\u003cli\u003eNumber of phases: 3-phase\u003c\/li\u003e\n\u003cli\u003eLocking: No\u003c\/li\u003e\n\u003cli\u003eDegree of protection against dust and water: IP20\u003c\/li\u003e\n\u003cli\u003eOperating temperature range: from -30 to +55°C\u003c\/li\u003e\n\u003cli\u003eManufacturer: Opas\u003c\/li\u003e\n\u003cli\u003eCountry of manufacturer: Turkey\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"OPAŞ","offers":[{"title":"10A \/ 3 poles","offer_id":49102867956045,"sku":"YPT304010","price":319.0,"currency_code":"CZK","in_stock":false},{"title":"16A \/ 3 poles","offer_id":49102867988813,"sku":"YPT304M16","price":287.0,"currency_code":"CZK","in_stock":false},{"title":"25A \/ 3 poles","offer_id":49102868021581,"sku":"YPT304M25","price":297.0,"currency_code":"CZK","in_stock":false},{"title":"32A \/ 3 poles","offer_id":49102868054349,"sku":"YPT304032","price":430.0,"currency_code":"CZK","in_stock":false},{"title":"40A \/ 3 poles","offer_id":49102868087117,"sku":"YPT304TR40","price":599.0,"currency_code":"CZK","in_stock":false},{"title":"63A \/ 3 poles","offer_id":49102868119885,"sku":"YPT304TR63","price":722.0,"currency_code":"CZK","in_stock":false},{"title":"80A \/ 3 poles","offer_id":49102868152653,"sku":"YPT304TR80","price":770.0,"currency_code":"CZK","in_stock":false},{"title":"100A \/ 3 poles","offer_id":49102868185421,"sku":"YPT304100","price":1909.0,"currency_code":"CZK","in_stock":false},{"title":"125A \/ 3 poles","offer_id":49102868218189,"sku":"YPT304125","price":1950.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_a6ef58fc-8451-43cf-be0f-dbf0b47c8982.jpg?v=1718448593"},{"product_id":"ochranne-trifazove-monitorovaci-rele-pro-kontrolu-fazi-vypadek-asym-sled","title":"Protective three-phase monitoring relay for phase failure\/asym\/sequence control","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePhase\n  regulation relay with phase sticking regulation, phase loss, asymmetric phases\n  (fixed 30%), with mounting on a single FKV-11 rail, TENSE\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAlgorithm\n  operations of the phase regulation relay: if all three phase or network\n  voltage connected in the correct order, all phase voltages are within permissible limits\n  – the relay is in operational condition and contacts 2-3 are closed, the LED lights up\n  the OUT LED. If the voltage of any phase changes by more than 30% (or\n  the total multi-directional change exceeds this limit), the ASM LED will light up and\n  contacts 2-3 will disconnect, contacts 1-2 will connect, and the OUT LED will turn off. After\n  the return of the voltage difference to the specified range, the contacts will switch back.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  specification\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eCount\n  phase 3\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated\n  current 5 A\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated\n  operating voltage AC 380 V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMinimum\n  operating voltage 200 V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMaximum\n  operating voltage 532 V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMaximum\n  power 3 W\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTotal\n  dimensions\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLength\n  85 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eHeight\n  77.6 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWidth\n  22.5 mm\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUser\n  properties\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003ePhase asymmetry regulation 30 %\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102870118733,"sku":"FKV-11","price":513.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_47eb20d2-abd8-42e1-8d58-d7c2eeb7e4ce.png?v=1718448617"},{"product_id":"trifazove-monitorovaci-rele-s-ptc-kontrolni-fazi-vypadek-asymetrie-sled","title":"Three-phase monitoring relay with PTC control phase failure\/asymmetry\/sequence","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThree-phase\n  relay for phase control with protection against phase loss, sticking, asymmetry (40\n  %), phase switching and winding temperature control, with zero conductor, Tense\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePhase\n  relay with phase presence monitoring, phase loss, phase sticking, asymmetry\n  phases (fixed 40%), phase switching order, with winding temperature control, with zero\n  conductor, with DIN rail mounting FKV-14P, TENSE\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAlgorithm\n  operation of the relay for phase control: if all three phase or\n  network voltage, connected in the correct order and the winding temperature is within acceptable\n  limits – the relay is in operational state and contacts 15-18 are closed, the LED lights up\n  diode OUT. If the voltage of any phase changes by more than 40% (or\n  the total multi-directional change exceeds this limit), contacts 15-18 will disconnect,\n  contacts 15-16 will close and the OUT indicator light will turn off. The same will happen if\n  the phase sequence is disrupted, the indicator light will also turn off.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eThe relay also reacts to the engine temperature exceeding\npermitted limits. When the parameters return to the established limits, the relay will return\nto the operational state.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102870151501,"sku":"FKV-14P","price":591.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_050ece25-9edb-4055-9baf-a09e9e98c3a1.png?v=1718448621"},{"product_id":"trifazove-monitorovaci-ochranne-rele-pro-kontrolu-fazi-vypadek-asym-pre-pompeti-1","title":"Three-phase monitoring\/protection relay for phase failure\/asym\/over-pump control","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003ePhase\n  protective relays are designed to protect devices with precise values\n  operating voltage and phase switching functions before errors that may occur in\n  due to the network voltage and the temperature of the motor.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFKV-24F\n  has a constant asymmetry of 11%. It can operate at a voltage from 180 to 500 V AC.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAsymmetry\n  means the difference between voltage values. Especially in three-phase loads, such as\n  motors, the high-voltage coil consumes a large current and the low-voltage coil\n  low voltage. Therefore, they operate unbalanced and the coils get damaged over time.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWhen there is\n  the device is turned on, contacts of the relay no. 1 (NC) and 2 (COM) are closed and\n  contacts no. 2 (COM) and 3 (NO) are open. If the voltage values are in\n  normal range, the LED (OUT) in the relay will light up; the terminals of relay 1 (NC)\n  and 2 (COM) are open, the terminals of relay 2 (COM) and 3 (NO) are closed.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIf\n  if the difference between the voltage values exceeds 11 %, the relay LED will turn off after approximately 1 second\n  and the contacts of relay 1 (NC) and 2 (COM) will close and the contacts of relay 2 (COM) and 3\n  (NO) will disconnect. If the difference between the voltage values decreases by 5 V, the relay LED\n  will light up and the contacts of relay 1 (NC) and 2 (COM) will disconnect and the contacts of relay\n  2 (COM) and 3 (NO) will close.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIf\n  the phase sequence is correct, the relay LED will light up; the terminals of relay 1 (NC) and 2 (COM)\n  are disconnected and the contacts of relay 2 (COM) and 3 (NO) are closed. If the\n  the phase sequence is incorrect, the relay LED will light up, the relay LED will turn off and the contacts of the relay\n  no. 1 (NC) and 2 (COM) will close and the contacts of relay no. 2 (COM) and 3 (NO) will\n  will disconnect.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIf\n  the voltage value exceeds the set high voltage value, the LED will light up\n  high voltage error indicator LED (U\u0026gt;). If the voltage value\n  does not drop below the normal value within 2 seconds, the device will have a high voltage error\n  voltage. In this position, the relay LED will turn off, the contacts of relay no. 1 (NC) and 2\n  (COM) are closed and the contacts of relay no. 2 (COM) and 3 (NO) are open.\n  When the voltage value drops below the set high voltage value by 5 V, the LED\n  the high voltage error indicator LED will turn off and the device will start counting down\n  the error delay time (t). After the waiting time for the error has elapsed, the LED will light up\n  relay LED, the contacts of relay no. 1 (NC) and 2 (COM) are open and the contacts\n  the contacts of relay no. 2 (COM) and 3 (NO) are closed.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIf\n  the voltage values drop below the set low voltage value, the LED will light up\n  LED indicating low voltage error (U \u003c). If the voltage values\n  during the error delay time does not increase to the normal value, the device will have\n  the low voltage error. In this position, the relay LED will turn off, the terminals of relay no.\n  1 (NC) and 2 (COM) are closed and the contacts of relay no. 2 (COM) and 3 (NO) are\n  open. If the voltage value exceeds the set low voltage value by\n  5 V, the LED indicating low voltage error will turn off and the device will start\n  count down the error delay time (t). After the error delay time has elapsed,\n  the relay LED lights up and the contacts of relay no. 1 (NC) and 2 (COM) are open\n  and the contacts of relay no. 2 (COM) and 3 (NO) are closed.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMain\n  characteristics:\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperational\n  voltage (Un): 3x380 VAC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperational\n  frequency: 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperational\n  power: \u003c4 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperational\n  temperature: From -20 °C to 55 °C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLow\n  voltage: 180 VAC (fixed)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eHigh\n  voltage: 500 VAC (fixed)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAsymmetry:\n  ~% 11 (fixed)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWithout\n  neutral conductor: yes\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIndication:\n  5 LEDs\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eContact:\n  Active load 5A \/ 250 VAC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDiameter\n  cable: 2.5 mm2\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWeight:\n  \u0026lt;110 g.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMounting:\n  Mounting on DIN rail\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos minor-latin new roman mso-ascii-theme-font:minor-latin=\"\" mso-bidi-theme-font:minor-bidi=\"\" mso-bidi-language:ar-sa=\"\"\u003eProtection class: IP20\u003c\/span\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102870217037,"sku":"FKV-24F","price":512.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_deb3f65a-8948-4452-93d6-0a3774665d5d.png?v=1718448624"},{"product_id":"monitorovaci-ochranne-trifazove-rele-pro-kontrolu-prepeti-podpeti","title":"Monitoring\/protective three-phase relay for checking overvoltage, undervoltage","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRelay\n  to protect devices with sensitive operating voltages and undervoltage from\n  caused by network voltage disturbances. Single-phase. Manufactured by\n  TENSE.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDetailed\n  description\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eMonitoring\n  overvoltage and undervoltage relay GKM-11, single-phase\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eAdjustable\n  voltage protective relay GKM-11 (surge and undervoltage) is designed to measure\n  voltage as a prevention of faults by disconnecting the relay (disconnecting the load) in single-phase\n  distributions, switchboards, and devices. It monitors the voltage level in a single-phase\n  the system between L-N.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eUsing\n  of rotary potentiometers It is possible to set the upper and lower voltage limits at which\n  the relay output contact disconnects. Adjustable time delay \"DT\"\n  and \"RT\" allows eliminating too rapid unsolicited response.\n  Power is internally connected from the monitored voltage. The normal state is\n  indicated by a green LED. An error state is indicated by 2x red LED\n  \"LV\" and \"HV\" and the disconnection of the relay output contact.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  specification\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  voltage: 220 V AC, 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eHigh\n  Voltage: 230V-300V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eLow\n  Voltage: 150V-210V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTime\n  Delay: 0.5 s - 20 s.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTime\n  Reset: 0.5 s - 20 s.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  Power: \u003c6 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  Temperature: -20 °C ..... + 55 °C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDisplay:\n  3 LED diodes\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eType\n  Connection: DIN rail mounting.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWeight:\n  0.100 kg\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eContact:\n  5A \/ 250VAC Resistive load\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  Altitude: \u003c 2000 m\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eCable diameter: 2.5 mm2\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102870446413,"sku":"GKM-11","price":992.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_be30bf2e-baf0-4844-ae15-92774d0f735f.png?v=1718448638"},{"product_id":"krokovy-spinac-0-1-2-3-4-stupnovy-otocny-prepinac-1-2-poly-10-160a","title":"Step switch 0-1-2-3-4 step rotary switch, 1-2 poles, 10-160A","description":"\u003cp\u003e\u003cstrong\u003eStep switch 0-1-2-3-4, rotary switch, 1-2 poles, 10-160A, YPT114, manufacturer OPAŞ (Turkey)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10A, 16A, 25A, 32A, 40A, 63A, 100A, 125A, 160A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe step switch 0-1-2-3-4 can be used, for example, to select one of three phases and a generator for powering single-phase electrical appliances or to turn on one of several appliances \/ modes \/ steps of the processing program, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage switches\u003c\/strong\u003e are designed for manual switching of low voltage circuits. They are used for creating main and control circuits, turning on and off electric motors and other low-power devices. The advantages of switches in this series are compact dimensions, electrical and mechanical resistance, and also high switching capabilities.\u003c\/p\u003e\n\u003cp\u003eMulti-position scheme 0-1-2-3-4 is used for switching between different operating modes of the device (speed of movement, heating temperature).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign: Hinge\u003c\/li\u003e\n\u003cli\u003eDevice type: Rotary switch\u003c\/li\u003e\n\u003cli\u003eSwitching scheme: 0 - 1 - 2 - 3 - 4\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 1\u003c\/li\u003e\n\u003cli\u003eType: Built-in\u003c\/li\u003e\n\u003cli\u003eNumber of phases: Single-phase\u003c\/li\u003e\n\u003cli\u003eLocking: No\u003c\/li\u003e\n\u003cli\u003eDegree of protection against dust and water: IP20\u003c\/li\u003e\n\u003cli\u003eOperating temperature range: from -30 to +55°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OPAŞ","offers":[{"title":"10A \/ 1 fields","offer_id":49102870577485,"sku":"YPT114010","price":392.0,"currency_code":"CZK","in_stock":false},{"title":"10A \/ 2 poles","offer_id":49102870610253,"sku":"YPT214010","price":446.0,"currency_code":"CZK","in_stock":false},{"title":"16A \/ 1 fields","offer_id":49102870643021,"sku":"YPT114M16","price":435.0,"currency_code":"CZK","in_stock":true},{"title":"16A \/ 2 poles","offer_id":49102870675789,"sku":"YPT214M16","price":499.0,"currency_code":"CZK","in_stock":false},{"title":"25A \/ 1 fields","offer_id":49102870708557,"sku":"YPT114M25","price":626.0,"currency_code":"CZK","in_stock":false},{"title":"25A \/ 2 poles","offer_id":49102870741325,"sku":"YPT214M25","price":647.0,"currency_code":"CZK","in_stock":false},{"title":"32A \/ 1 fields","offer_id":49102870774093,"sku":"YPT114032","price":732.0,"currency_code":"CZK","in_stock":true},{"title":"32A \/ 2 poles","offer_id":49102870806861,"sku":"YPT214032","price":764.0,"currency_code":"CZK","in_stock":true},{"title":"40A \/ 1 fields","offer_id":49102870839629,"sku":"YPT114TR40","price":796.0,"currency_code":"CZK","in_stock":true},{"title":"40A \/ 2 poles","offer_id":49102870872397,"sku":"YPT214TR40","price":795.0,"currency_code":"CZK","in_stock":true},{"title":"63A \/ 1 fields","offer_id":49102870905165,"sku":"YPT114TR63","price":955.0,"currency_code":"CZK","in_stock":true},{"title":"63A \/ 2 poles","offer_id":49102870970701,"sku":"YPT214TR63","price":1114.0,"currency_code":"CZK","in_stock":true},{"title":"80A \/ 1 fields","offer_id":49102871003469,"sku":"YPT114TR80","price":1167.0,"currency_code":"CZK","in_stock":false},{"title":"80A \/ 2 poles","offer_id":49102871069005,"sku":"YPT214TR80","price":1249.0,"currency_code":"CZK","in_stock":false},{"title":"100A \/ 1 fields","offer_id":49102871101773,"sku":"YPT114100","price":1499.0,"currency_code":"CZK","in_stock":false},{"title":"100A \/ 2 poles","offer_id":49102871134541,"sku":"YPT214100","price":1920.0,"currency_code":"CZK","in_stock":true},{"title":"125A \/ 1 fields","offer_id":49102871167309,"sku":"YPT114125","price":1799.0,"currency_code":"CZK","in_stock":false},{"title":"125A \/ 2 poles","offer_id":49102871200077,"sku":"YPT214125","price":2540.0,"currency_code":"CZK","in_stock":false},{"title":"160A \/ 1 fields","offer_id":49102871232845,"sku":"YPT114160","price":2099.0,"currency_code":"CZK","in_stock":false},{"title":"160A \/ 2 poles","offer_id":49102871265613,"sku":"YPT214160","price":3600.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_9ab3c6b0-10fc-469b-913b-d128dec79af1.jpg?v=1718448690"},{"product_id":"krokovy-spinac-0-1-2-3-4-5-6-7-stupnovy-otocny-prepinac-1-polu-10-160a","title":"Step switch 0-1-2-3-4-5-6-7 step rotary switch, 1 poles, 10-160A","description":"\u003cp\u003e\u003cstrong\u003eStep (incremental) switch 0-1-2-3-4-5-6-7, rotary switch, 1 pole, 10-160A, YPT117 by manufacturer OPAŞ (Turkey)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10A, 16A, 25A, 32A, 40A, 63A, 100A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe step switch 0-1-2-3-4-5-6-7 can be used, for example, to turn on one of several appliances \/ modes \/ steps of the processing program, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage switches\u003c\/strong\u003e are designed for manual switching of low voltage circuits. They are used for creating main and control circuits, turning on and off electric motors and other low-power devices. The advantages of switches in this series are compact dimensions, electrical and mechanical resistance.\u003c\/p\u003e\n\u003cp\u003eThe multiposition scheme 0-1-2-3-4-5-6-7 is used for switching between different operating modes of the device (speed of movement, heating temperature).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign execution: Articulated\u003c\/li\u003e\n\u003cli\u003eType of device: Rotary switch\u003c\/li\u003e\n\u003cli\u003eSwitching scheme: 0 - 1 - 2 - 3 - 4 - 5 - 6 - 7\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 1\u003c\/li\u003e\n\u003cli\u003eType: Built-in\u003c\/li\u003e\n\u003cli\u003eNumber of phases: Single-phase\u003c\/li\u003e\n\u003cli\u003eSecuring: No\u003c\/li\u003e\n\u003cli\u003eDegree of protection against dust and water: IP20\u003c\/li\u003e\n\u003cli\u003eOperating temperature range: from -30 to +55°C\u003c\/li\u003e\n\u003cli\u003eManufacturer: Opas\u003c\/li\u003e\n\u003cli\u003eCountry of manufacturer: Turkey\u003c\/li\u003e\n\u003cli\u003eNumber of working positions: 8\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"OPAŞ","offers":[{"title":"10A \/ 1 fields","offer_id":49102871396685,"sku":"YPT117010","price":674.0,"currency_code":"CZK","in_stock":false},{"title":"16A \/ 1 fields","offer_id":49102871429453,"sku":"YPT117M16","price":690.0,"currency_code":"CZK","in_stock":false},{"title":"25A \/ 1 fields","offer_id":49102871462221,"sku":"YPT117M25","price":806.0,"currency_code":"CZK","in_stock":false},{"title":"32A \/ 1 fields","offer_id":49102871560525,"sku":"YPT117032","price":944.0,"currency_code":"CZK","in_stock":true},{"title":"40A \/ 1 fields","offer_id":49102871593293,"sku":"YPT117TR40","price":1061.0,"currency_code":"CZK","in_stock":true},{"title":"63A \/ 1 fields","offer_id":49102871626061,"sku":"YPT117TR63","price":1379.0,"currency_code":"CZK","in_stock":false},{"title":"80A \/ 1 fields","offer_id":49102871691597,"sku":"YPT117TR80","price":1697.0,"currency_code":"CZK","in_stock":true},{"title":"100A \/ 1 fields","offer_id":49102871724365,"sku":"YPT117100","price":4136.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_429c68a7-4fd1-4979-a1bc-33c8a0e29949.jpg?v=1718448724"},{"product_id":"oddelovaci-pomocne-rele-releovy-modul-patice-rele-na-din-listu-6-a-no-nc","title":"Separating auxiliary relay Relay module - socket + relay on din rail, 6 A, NO+NC","description":"\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRelay\n  interface with a mounting block, interface module: 6A, 12-24V, AC\/DC, HB+NC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBlock\n  interface HF-41F consists of the basic module 41F-1Z-C2-1 and a plug-in\n  of the miniature relay HF41F\/24-ZT with power contacts. It is designed for galvanic\n  isolation, increased switching capacity, and amplification of the control signal coming\n  from PLC.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eFeatures\n  and advantages\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eEnsures\n  galvanic isolation and switching of power and signal circuits.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eInstallation\n  on a standard DIN rail.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eReplacement\n  of the relay element without disassembling the entire module.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eSavings\n  Places\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eBuilt-in\n  LED indicator\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eTechnical\n  Properties\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated\n  Input voltage: 12-24V, AC\/DC\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated\n  Operating voltage AC: 250 V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated\n  Operating voltage DC: 30 V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated\n  Current: 6 A\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eContacts:\n  NO+NZ\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eIndication:\n  Green LED relay status indicator\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  Temperature: -20...+55 °C\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDegree\n  Protection: IP20\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\u003cp\u003e\n\n\u003cspan lang=\"CS\" style='font-size:12.0pt;line-height:115%;font-family:\"Aptos\",sans-serif;\nmso-ascii-theme-font:minor-latin;mso-fareast-font-family:Aptos;mso-fareast-theme-font:\nminor-latin;mso-hansi-theme-font:minor-latin;mso-bidi-font-family:\"Times New Roman\";\nmso-bidi-theme-font:minor-bidi;mso-ansi-language:CS;mso-fareast-language:EN-US;\nmso-bidi-language:AR-SA'\u003eModule width: 6 mm \u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102872150349,"sku":"HF-41F","price":190.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_39fe3287-a608-48d1-b26e-ebb443fd8cdd.webp?v=1718448657"},{"product_id":"regulator-teploty-pro-montaz-do-panelu-on-off-proportional-az-400ºc","title":"Temperature regulator for mounting in an ON-OFF\/Proportional panel, up to 400ºC","description":"\u003cp\u003e\u003cstrong\u003eThermostat\/ 2-point temperature controller for panel mounting ON\/OFF ON\/OFF or Proportional control mode, measurement range 0°C ... +400°C, resolution \/ step 1ºC (made in Turkey, TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eControl and monitoring of thermal processes in heating, air conditioning, and ventilation systems, building automation, industrial plants.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eSensor type: J type, Fe-Const, T\/C\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRelay outputs OUT (NO+NC) 250VAC, 2A\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003eHysteresis\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eEEPROM memory for storing settings\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003ePlease remember to order our temperature sensors - type J thermocouple Fe-Const (metric 6\/8) with a temperature measurement range of: -100 °C – +600 °C. It can be with a cable 1 m, 1.5 m, 2 m, 2.5 m, 3 m, 4 m, and 5 meters long.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102872248653,"sku":"AD-96","price":891.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/98b116887cf73352daeceb17585d029e.png?v=1761561960"},{"product_id":"hladinova-sonda-nerezova-v-pvc-krytu-pro-regulator-hladiny-vody-sse-10-tense","title":"Stainless steel level probe in a PVC cover for the SSE-10 TENSE water level regulator","description":"\u003cp\u003e\u003cstrong\u003eStainless steel level probe in PVC cover for the SSE-10 TENSE water level regulator\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eA very practical solution for water tanks (metal and plastic) - guarantee of long service life, convenient use, quick replacement if necessary.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003edetection probe is an electrode that, in conjunction with a suitable evaluation device, is used to detect levels, e.g. in wells, boreholes, reservoirs\u003c\/li\u003e\n\u003cli\u003eintended for operation in electrically conductive liquids as well as mechanically contaminated ones in the temperature range: +1.. +90 °C\u003c\/li\u003e\n\u003cli\u003esuitable for use in drinking water\u003c\/li\u003e\n\u003cli\u003estainless steel single-pole electrode housed in a PVC cover, intended for hanging or fixing via a sleeve on the tank wall\u003c\/li\u003e\n\u003cli\u003efor the proper functioning of the probe, it is necessary to ensure that the electrode of the probe is clean and free of impurities that could prevent contact of the electrode with the liquid. If the electrode becomes clogged, the probe could malfunction.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eScrew connection of the wire, up to 2.5 mm2. \u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102872281421,"sku":"SSE-10","price":123.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/file_67f251a6-28ae-4170-94e4-4b21ccde54ea.png?v=1718448664"},{"product_id":"regulator-vysky-hladiny-plneni-vypousteni-spinace-hladiny-hladinomer-do-vrtu","title":"Level filling height regulator, discharge level switch, level gauge into borehole SSR-05","description":"\u003ch3\u003e\n\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eRelay\n  for liquid level regulation TENSE SSR-05 for wells, tanks, reservoirs or\n  pits.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eHome\n  surface and submersible centrifugal water pumps are usually equipped with\n  thermoplastic hydraulic components and cannot operate without water under\n  conditions of 'dry friction', even for a short period.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eWater\n  not only lubricates the friction surfaces but also acts as a coolant, absorbs and dissipates\n  the heat generated by friction. A centrifugal pump must be protected from possible\n  running dry or lack of water. Among potentially hazardous applications\n  centrifugal pumps due to the risk of running dry involves pumping water from\n  wells or boreholes with low or insufficient flow, pumping water from tanks\n  or storage tanks with a finite or refillable volume and operation\n  in pressure-boosting systems. A pump without intelligence and functional\n  protective functions cannot independently detect a lack of water in the suction pipe\n  or in the well and turn off.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eRelay\n  SSR-05 for controlling the liquid level in a well, tank, reservoir, or\n  the well is a simple and reliable device for monitoring the level in the well\n  using two or three level sensors with adjustable sensor sensitivity and\n  LED indication of the water level in the well\/reservoir. The SSR-05 relay can also be used to\n  pump control for filling the tank or signaling a leak and shutting off\n  the pump.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eTherefore\n  is more suitable to protect the pump, which is at risk of running dry or lack of\n  detecting water in the suction pipe. The SSR-05 relay for monitoring the liquid level in the well,\n  tank, reservoir, or well is one of the devices capable of reliably\n  eliminate potential risk of the pump running dry.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eRated\n  voltage: 220 V AC,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eOperating\n  range: 170 V-260 V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eOperating\n  frequency: 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eOperating\n  power: \u0026lt;3 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eOperating\n  temperature: -10...+50\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eConnection:\n  with terminal\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003eDimensions\n  (mm) 44x75x85\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\" style=\"font-weight: normal;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size: 12pt; line-height: 115%; font-family: Aptos, sans-serif; font-weight: normal;\"\u003eWeight 250 g.\u003c\/span\u003e\n\u003c\/h3\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102872346957,"sku":"SSR-05","price":764.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/SSR-05_TENSE_Principal_Elektrik_water_level.png?v=1738751843"},{"product_id":"hladinovy-spinac-hlidani-hladiny-plneni-vypousteni-hladinomer-do-vrtu","title":"Level switch \/ Level monitoring for filling, draining level gauge into well VSR-05 TENSE","description":"\u003ch3\u003e\n\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRelay\n  for regulating the water level in a tank, well, borehole, expansion tank. Control\n  pumping or transferring water, the possibility of using three or two level\n  sensors. Sensor sensitivity settings. VSR-05, TENSE\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDon't forget\n  please order water level sensors and a 2-amp circuit breaker for protection\n  input and output channels of this device (2 pieces)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated\n  voltage: 220V AC,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  range: 170V-260V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  frequency: 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  power: \u003c3 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  temperature: -10...+50\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnection:\n  with clamp\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDimensions\n  (mm) 22.5x75x85\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eWeight 250 g.\u003c\/span\u003e\n\u003c\/h3\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102872412493,"sku":"VSR-05","price":765.0,"currency_code":"CZK","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/643f979a7a582e895ea3fd644677f054.png?v=1771411689"},{"product_id":"regulator-vysky-hladiny-hladinomer-do-vrtu-s-casovacem-spinace-hladiny","title":"Level regulator, level gauge for well with timer level switch SSR-05D TENSE","description":"\u003ch3\u003e\n\u003cdiv\u003e\n\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" hspace=\"0\" vspace=\"0\" align=\"center\"\u003e\n \u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd valign=\"top\" align=\"left\" style=\"padding-top:0cm;padding-right:9.0pt;\n  padding-bottom:0cm;padding-left:9.0pt\"\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRegulation\n  water levels in a well, borehole, tank, expansion tank. For pumping or\n  for draining water from the tank, it is possible to use three or two level sensors.\n  Sensor sensitivity settings + response delay time settings. SSR-05D, TENSE\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThis\n  the water level relay has a number of important differences from other similar\n  of the level control relays presented on this website.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eThis\n  the relay is digital, meaning that inside there is a microprocessor that controls the operation\n  of the entire device. This allows for the implementation of some additional functions that not only\n  to increase comfort in use, but also extend the lifespan of the level sensors\n  water.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e1)\n  The current between the water level sensors does not flow continuously, but in pulses – this allows\n  the lifespan of electrodes submerged in water increases more than 2 times!\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e2)\n  SSR-05D has a built-in pump delay timer. A useful feature if\n  for example, the relay is used in a well (or borehole), where the water level changes in\n  depending on the season – accordingly, you will not have to change the position\n  upper sensor – it is sufficient to change the delay time on the relay.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e3) This\n  the level relay is additionally equipped with 3 LEDs that indicate how the water\n  filled into the tank – upper, middle, and lower level. I agree that it is\n  advantageous if the relay is installed inside the house and the tank is on the roof, in\n  in the basement or on the street.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eElectrodes\n  (liquid level sensors) are not included in the set.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDo not forget\n  please order water level sensors and a 2-amp circuit breaker for protection\n  input and output channels of this device (2 pieces).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eRated\n  voltage: 220 V AC,\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  range: 150 V-260 V\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  frequency: 50\/60 Hz.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  power: \u003c3 VA\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eOperating\n  temperature: -10...+50\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eConnection:\n  with terminal block\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eDimensions\n  (mm) 44x75x85\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003eWeight\n  250 g\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"CS\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/td\u003e\n \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cspan lang=\"CS\" style=\"font-size:12.0pt;line-height:115%;font-family:\" aptos mso-ascii-theme-font:minor-latin minor-latin new roman mso-bidi-theme-font:minor-bidi mso-bidi-language:ar-sa\u003eConnection type: DIN rail + screws\u003c\/span\u003e\n\u003c\/h3\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":49102872904013,"sku":"SSR-05D","price":850.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/8191\/0349\/files\/SSR-05D.png?v=1738752609"}],"url":"https:\/\/pelek.eu\/en-ie\/collections\/vsechny-produkty.oembed","provider":"pelek","version":"1.0","type":"link"}